User Manual
Commercial School Milk Coolers

Inspection

Please read this manual thoroughly prior to equipment set-up, operation and maintenance.
When the equipment is received, all items should be carefully checked against the bill of landing to insure
all crates and cartons have been received. All units should be inspected for concealed damage by uncrating
the units immediately. If any damage is found, it should be reported to the carrier at once, and a claim should
be filed with the carrier. This equipment has been inspected and tested in the Avantco Refrigeration facility
and has been crated in accordance with transportation rules and guidelines. Manufacturer is not responsible
for freight loss or damage.

Installation

General
Take care when removing the skid so that it will not damage the cooler's finish.
Location
The self-contained refrigeration system located at the bottom of the cabinet requires free air access for
proper operation. The back of the cabinet may be positioned against a wall, however, there must be a mini-
mum of four inches of clearance between the sides and a wall. It is necessary to properly level the cooler to
provide adequate drainage and efficient functioning of the unit.
Electrical
Check the proposed outlet to be used to ensure that the voltage, phase, and current carrying capacity of the
circuit from the electrical panel correspond to the requirements of the cabinet. Plug into a standard 120-volt
outlet. NEVER use an extension cord to power any unit. All wiring between the electrical panel and the unit
must be done in accordance with the National Electric Code and all state and local codes. Refer to the Serial
Tag for all pertinent electrical information.
General Operation
The milk coolers are cooled entirely by cold wall because of copper coils completely encircling the perimeter
of the storage compartment. During the refrigeration process, heat is removed through the evaporator tubing
and expelled through the condensing unit. It is important that the flow of air through the side louvers is not
restricted to ensure the condensing unit operates properly. Under normal operating conditions, any frost that
might accumulate on the walls during the "on" cycle of the condensing unit may melt during the "off" cycle.
Drains are installed in all milk coolers to accommodate melting frost. Coolers need to be installed over a floor
drain as there is no catch pan for melting frost.