Avantco 178SS2F4HC Посібник користувача - Сторінка 4
Переглянути онлайн або завантажити pdf Посібник користувача для Морозильна камера Avantco 178SS2F4HC. Avantco 178SS2F4HC 9 сторінок. Reach-in refrigerators and freezers
Також для Avantco 178SS2F4HC: Посібник користувача (8 сторінок)
1. Remove the bottom vent, which is held on by loosening the 4 Phillips head screws that hold it
on. You do not need to remove the whole way, as the vent will slide up and out.
2. Remove the top panel next. It is held on with 2 small screws. Once the screws are out, the top
panel will hinge up.
3. Remove the small Philips head screws at the top and bottom door hinge where it attaches to the
brackets. Be careful not to lose the small washers.
4. Next take off the top bracket. It is held on with 3 bolts.
5. The door should come off at this point.
Note:
Do not lose the small round brass spacer on the bottom hinge!
6. Remove the bottom bracket. It is held on with 3 bolts.
7. Replace the bottom hinge with the new left hand bottom bracket. It is held on with 3 bolts.
8. At this point, you will need to adjust the top and bottom spring tensioners so the door will close
properly.
9. Put the door on the bottom hinge on the left side. You will need to reuse the brass spacer from
step 5.
10. Next, place the top bracket on the top of the door before bolting it to the unit with the 3 bolts.
11. Replace the small screws on the top and bottom of the bracket and door spring. Make sure the
door is on properly before you do this.
12. Reattach the bottom vent and the top panel.
Cabinet Location Guidelines
• Install the unit on strong and leveled surfaces.
• If the surface is uneven, the unit may be noisy.
• The unit may malfunction if the surface is uneven.
• Install the unit in an indoor, well-ventilated area.
• For best performance, please maintain clearance of 6" on the back of the unit.
• Do not use outdoors. For indoor use only.
• Avoid direct sunlight.
• Avoid installation in a high-humidity and/or dusty area.
• Humidity above 60% can cause the unit to rust, collect condensation, and may
decrease efficiency.
• Dust collected on the condenser coil will cause the unit to malfunction.
• Malfunctions due to temperatures above 75 degrees Fahrenheit, humidity above 60%, or
improperly maintained condenser coil will void the warranty.
• Select a location away from heat and moisture-generating equipment.
• Ambient temperatures above 75 degrees Fahrenheit may cause the compressor
to malfunction.
• Malfunctions due to ambient temperatures above 75 degrees Fahrenheit will void
the warranty.
• Do not install the unit inside a closet or alcove.