ALIENTEK
6.2 Mode set
Step set: In the temp adjust UI, rotating the encoder to adjust the set temp to step by this
value.
Boost set: Used in boost mode, including boost temp and boost time (boost countdown).
Four levels: Used in noamal moed,in temp adjust UI,clicking the encoder,set temp cycle in
four levels (default 200 300 350 450℃).
6.3 Sleep set
Sleep temp: default 200℃.
Sleep time: In units of minutes, the setting range is 1~20 and 99. That is the time① in the
control system flow chart of Fig. 1. In the normal working state, and the system enters the sleep
state without using the handle, rotating or clicking the encoder within the specified sleep time.
Note: When set to 99, it means not sleeping! Do not sleep and will not enter standby!
Standby: Standby time. In units of minutes. The setting range is 0~20. That is the time② in
the control system flow chart of Fig. 1. In the sleep state, the system enters the standby state
without using the handle, rotating or clicking the encoder within the specified standby time. Note:
When set to 0, it means that the soldering iron skips sleep and direct standby!
T100 Smart Soldering station
Fig 6.3 mode set
Fig 6.4 sleep set
7