AEG DD8691 Посібник з експлуатації та встановлення - Сторінка 4
Переглянути онлайн або завантажити pdf Посібник з експлуатації та встановлення для Вентиляційна витяжка AEG DD8691. AEG DD8691 17 сторінок.
The air outlet installation must comply with the regulations laid down
by the relevant authorities.
•
When the unit is used in its extractor version, a sufficiently large
ventilation hole must be provided, with dimensions that are
approximately the same as the outlet hole.
•
National and regional building regulations impose a number of
restrictions on using hoods and fuel-burning appliances connected
to a chimney, such as coal or oil room-heaters and gas fires, in the
same room.
•
Hoods can only be used safely with appliances connected to a
chimney if the room and/or flat (air/environment combination) is
ventilated from outside using a suitable ventilation hole approxi-
mately 500-600 cm
being created during operation of the hood.
•
If you have any doubts, contact the relevant controlling authority or
building inspector's office.
•
Since the rule for rooms with fuel burning appliances is "outlet hole
of the same size as the ventilation hole", a hole of 500-600 cm
which is to say a larger hole, could reduce the performance of the
extractor hood.
•
If the hood is used in its filtering function, it will operate simply and
safely in the above conditions without the need for any of the
aforementioned measures.
•
When the hood is used in its extractor function, the following rules
must be followed to obtain optimal operation:
— short and straight outlet hose
— keep bends in outlet hose to a minimum
— never install the hoses with an acute angle, they must
always follow a gentle curve only
— keep the hose as large as possible (preferably the same diameter
as the outlet hole).
•
Failure to observe these basic instructions will drastically reduce the
performance and increase the noise levels of the extractor hood.
2
large to avoid the possibility of a depression
2
,
63