Maintenance Safety

Only use parts that are supplied or approved by Aqua Control. Use of other parts may result in poor performance that could
create a hazardous situation and will void the warranty.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or a similarly qualified person in
order to avoid a hazard.
Unplug the system and refer servicing to a qualified electrician for any of the following conditions:
When compressor fan, outlet, or other electrical components need service.
If the cabinet is producing unusual noises or odors.
After any accidental flooding prior to start-up.
Ground Instructions
This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by
providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with an
appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance
with all local codes and ordinances.
WARNING—Improper installation of the grounding plug can result in electric shock. When repair or replacement of the cord
or plug is required, do not connect the grounding wire to either flat blade terminal. The wire with insulation having an outer
surface that is green with or without yellow strips is the grounding wire.
Check with a qualified electrician or service person when the grounding instructions are not completely understood or when
in doubt as to whether the product is properly grounded. Do not modify the plug provided. If it does not fit the outlet, have
the proper outlet installed by a qualified electrician. Only connect the product to an outlet having the same configuration as
the plug. Do not use an adapter with this product.

Initial Inspection

Open and Inspect Product Immediately Upon Receiving Your Order
Product Damaged in Delivery
The Aqua Control Aeration System was properly packed and accepted by the freight carrier for shipment. It is their
responsibility to deliver they system in perfect condition.
Apparent Damage or Loss
If upon delivery, the equipment or container indicates "Damage in Transit," such goods should be refused until the freight
company's agent has noted such damage on the freight bill. A copy of this bill should be given to you, noting the nature and
extent of the damage. If any part of the shipment is lost in transit, have that shortage noted on the freight bill by the shipping
agent.
Concealed Damage
If damage is discovered that was not apparent upon delivery, notify the freight company immediately to inspect the damaged
equipment. The inspector should provide a "Concealed Bad Order" report. Inspections must be requested within seven days
of delivery. Do not move damaged goods from the original point of delivery. Retain all original packaging/containers for
inspection. File a "Full Value Replacement" claim against the freight company.
Systems Materials List
Upon receipt, inspect to ensure that all of the components are included. If your aeration system has experienced damage from
shipping, promptly report the damage to the delivery company. Verify that you have received the following equipment:
Compressor(s): Located inside the cabinet. The compressor is 115 V or 230 V single phase and includes a power cord
with a three-pronged plug that should be plugged into a Class A GFCI receptacle box.
Airpod Diffuser Base: Flexible membrane tube or disc diffuser(s) are mounted on their own base that is weighted at the
factory for easy sinking and installation.
2 — Aqua Control, Inc.