INSTRUCTIONS
INSTALLATION
1.
Remove chiller and accessories from box. Examine for damages.
2.
Do not install the chiller outdoors. (Fig. 1)
3.
Place the chiller in a well ventilated area away from flammables, high temperature, direct sunlight, moisture or
dust. (Fig. 2)
4.
Place chiller on a stable, flat, even surface. (Fig. 3)
5.
Allow at least 2' around front, back and side of chiller for proper ventilation. Do not store chiller in a closed
location that does not receive air flow such as a closet or cabinet. Chiller must receive air flow. (A fan may be
required to draw warm air away from chiller). Keep away from heat sources to maintain optimal temperature.
Maximum operating temperature for this chiller is 95˚ Fahrenheit. (Fig. 4)
6.
Do not cover the chiller while in operation. Do not place items on top of unit.
7.
Chiller requires a water pump or external filter (not included). Use with a pump rated at 790-1500GPH (gallons
per hour). Do not use a pump with more than 19 feet of head pressure rating. Inadequate equipment can cause
water leakage or other damage. (Fig. 6)
8.
Do not put the unit upside down; it will cause damage to the unit. If unit is moved for any reason you must wait
20 minutes before turning unit on. (Fig.7)
9.
Do not operate chiller if you smell smoke or there is burning.
10. Do not use extension cords. Create a drip loop to prevent water from running the length of the cord. Keep all
connections dry and off the ground.
11. Do not allow water or salt to come in contact with thermostat or power cord.
12. Assemble inlet and outlet plumbing fittings and connect to the chiller. Make sure seal rings are properly
positioned.
2