Web Interface:

Along with the front panel controls, you can also control the Matrix Switch with a web interface. The
advantage of using the web interface is that you have access to more features in the Matrix Switch than
you would by only using the front panel controls such as Image Enhancement, access to a Test Pattern
Generator, and HDB
ase
To connect to the Matrix Switch and access the Web interface:
1. Connect the LAN port on the rear of the Matrix Switch into an active access point or router
2. Make sure your computer is on the same network
3. Open any web browser and type in the IP address of the Matrix Switch.
4. Press and Hold Inputs 1&4 for 5 seconds to enable DHCP
5. Press and Hold Inputs 3&4 for 5 Seconds to read IP and MAC Addresses
*NOTE - The default IP address is 192.168.1.239

Back Panel:

IR Ports
Used for IR extension over HDBT. Choose IR Input type using the dipswitch on the back of the unit (insert
pic of dipswitch).
• IR Eye = IR from remote/emitter
• IR Pass = IR direct from control system
• IR can be routed. By default, the switch comes in:
• IN1/OUT1 = Bound to HDBT Input 1
• IN2/OUT2 = Bound to HDBT Input 2
• IN3/OUT3 = Bound to HDBT Output 1
• IN4/OUT4 = Bound to HDBT Output 2
MIC IN
Allows for a mic to be injected into the extracted audio outputs (Show Pic). Select Microphone type by
using the dipswitch located next to the input.
Line In = Line level input (PC, Phone, etc..)
MIC = Microphone input for dynamic microphones
48V = Microphone input for condenser microphones. Provides 48V Phantom Power.
T compatibility mode. See the owner's manual for the specifics.