Dell PowerEdge 1300 Посібник з оновлення - Сторінка 22

Переглянути онлайн або завантажити pdf Посібник з оновлення для Сервер Dell PowerEdge 1300. Dell PowerEdge 1300 23 сторінки. Video update
Також для Dell PowerEdge 1300: Посібник з оновлення (24 сторінок), Посібник з оновлення (2 сторінок)

Dell PowerEdge 1300 Посібник з оновлення
support.dell.com
!") &% '"
To reassemble the system and perform verification checks, perform the following
steps.
NOTE: The following procedures apply to PowerEdge 2300, 4300, and 4350 systems.
For PowerEdge 1300 systems, see step 7 under "Installing Upgrade Microprocessors
in the PowerEdge 1300", found earlier in this document.
1.
Close the computer panel doors (for PowerEdge 4350 systems only) or replace
the covers and front bezel, and reconnect your computer and peripherals to their
power sources and turn them on.
As the system boots, it detects the presence of the new microprocessor and
automatically changes the system configuration information in the System Setup
program. The following message appears:
Second processor detected
2.
Enter the System Setup program and confirm that the top line in the system data
area correctly identifies the installed microprocessor(s). By default, the serial
numbers of Pentium III microprocessors are not displayed. See the procedures in
"Using the System Setup Program" in your User's Guide for accessing and mod-
ifying entries in the System Setup screens.
Reset the chassis intrusion detector while in the System Setup program by
changing Chassis Intrusion to Not Detected.
NOTE: If a setup password has been assigned by someone else, contact your
network administrator for information on resetting the chassis intrusion detector.
3.
Run the Dell Diagnostics to verify that the new microprocessor is operating
correctly.
See your User's Guide and your Installation and Troubleshooting Guide for addi-
tional information on running the Dell Diagnostics and troubleshooting any
problems that may occur.
Dell PowerEdge Systems — Microprocessor Upgrade
1-19