S A F E T Y N O T E S
Gloves should be worn during installation to prevent crushing and cutting injuries.
The product may only be used for bathing, hygienic and body cleaning purposes.
Children as well as adults with physical, mental and ⁄or sensoric impairments must
not use this product without proper supervision. Persons under the influence of
alcohol or drugs are prohibited from using this product.
The product may not be used as a holding handle. A separate handle must be
installed.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The plumbing codes applicable in the respective countries must be observed.
⁄ During installation of the product by qualified trained personnel, make sure that the
entire fastening surface is even and smooth (no protruding seams or tile offset), that
the finish of the wall is suitable to apply the product and has no weak points.
⁄ The product is not designed to be used with steam baths!
T H E R M O S T A T I C M I X E R I N C O N J U N C T I O N W I T H C O M -
B I N A T I O N B O I L E R S
⁄ If fitting a hand shower remove the water limiter from the shower.
S P E C I A L I N F O R M A T I O N F O R U K
If installing this product with a pump, please be aware that it has to have negative
head switching. This product will not function with a positive head pump.
T E C H N I C A L D A T A
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections G 1⁄2:
Thermal disinfection:
⁄ Safety against backflow
⁄ The product is exclusively designed for drinking water!
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
A D J U S T M E N T (see page 06)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the output
differs from the temperature set on the thermostat.
F A U L T
⁄ Insufficient water
⁄ Crossflow, hot water being forced into cold water pipe, or
vice versa, when mixer is closed
⁄ Spout temperature does not correspond with temperature
set
⁄ Temperature regulation not possible
⁄ Instantaneous heater didn't work with thermostat
⁄ Shower or spout dripping
A S S E M B L Y (see page 04)
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
65°C
150 mm
cold right - hot left
max. 70°C ⁄ 4 min
C A U S E
⁄ Supply pressure inadequate
⁄ Regulator filter dirty
⁄ Shower filter seal dirty
⁄ Backflow preventers dirty or leaking
⁄ Thermostat has not been adjusted
⁄ Hot water temperature too low
⁄ thermo cartridge calcified
⁄ Filters are dirty
⁄ check valve hasn't moved back
⁄ Flow limiter in handshower isn't removed
⁄ Dirt or sedimentation on valve seat, shut-off unit damaged
M A I N T E N A N C E (see page 11)
⁄ The check valves must be checked regularly according to DIN EN 1717
in accordance with national or regional regulations (at least once a year).
⁄ To guarantee the smooth running of the thermostat, it is necessary from
time to time to turn the thermostat from total hot to total cold.
D I M E N S I O N S (see page 06)
F L O W D I A G R A M (see page 06)
Shower outlet
Outlet for additional consumer (free flow)
Outlet for additional consumer (free flow)
S P A R E P A R T S (see page 10)
C L E A N I N G (see page 12)
O P E R A T I O N (see page 09)
R E M E D Y
⁄ Check water pressure (If a pump has been installed check
to see if the pump is working).
⁄ Clean filter in front of the mixer and on the MTC-thermo car-
tridge
⁄ Clean filter seal between shower and hose
⁄ Clean backflow preventers, exchange if necessary
⁄ Adjust thermostat
⁄ Increase hot water temperature to 42 ºC to 65 ºC
⁄ Exchange thermo cartridge
⁄ Clean the filter ⁄ exchange filter
⁄ Exchange check valves
⁄ Remove flow limiter
⁄ Exchange shut-off unit
0 3