ACU-RITE 02005TBDI Інструкція з експлуатації - Сторінка 12
Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Метеостанція ACU-RITE 02005TBDI. ACU-RITE 02005TBDI 16 сторінок.
Replace Intelli-Time
Intelli-Time technology is
powered by a pre-installed
coin-cell battery that stores
the time and date settings.
The battery has a shelf life of
several years. To replace the
Intelli-Time battery:
1. Locate the coin cell
battery inside the battery
compartment of display
unit. Unscrew and remove
the compartment cover.
2. Insert 1 x CR2032 coin cell battery into the battery compartment, as shown.
Install battery with "+" positive terminal facing OUT.
3. Screw in the battery cover.
Calibration
Calibrate Weather Forecast
The forecast can be calibrated on the display unit to improve accuracy when
sensor placement or environmental factors impact your data accuracy. The
calibration increases or decreases the amount of moisture in the forecast
algorithm. For example, if you feel the forecast is showing rain too often you
may want to remove 10% of the moisture from the forecast equation.
1. To enter calibration mode, press and HOLD the "p" and "q" buttons for at
least 3 seconds.
2. The "
" will begin flashing, indicating it is ready to be calibrated.
3. Press the "p" button to increase moisture in the forecast or press the "q"
button to remove moisture from the forecast.
4. Press the "SET" button to confirm the calibration adjustment, or after 20
seconds of inactivity the display will automatically save your adjustments
and exit calibration mode.
Clock Battery
®
12
CR2032
3V