Symptom: Unit displays video for only 1 sec, then goes dark with no on screen display or video.
Cure: Replace AWP1058 and AWZ6173
Models Covered: PDPV402
Tip Date: February 12 2001
The Tech Name: Jeff Andrews
Symptom: Picture is all white and shuts down. Standby light seems normal.
Cure: VH is low. Scan module is loading. Disconnect and check for short to isolate.
Models Covered: PDPV401, PDPV402, PDPV402/1
Tip Date: January 31 2001
The Tech Name: Bob Shoemaker
Symptom: A bright white horizontal stripe appears across the screen. The width of the stripe is 1/4 of the screen height.
Cure: If stripe is in the upper half of the screen, swap the cables in connectors Y11 and Y13 of the Y- Drive A module. If
the problem is in the lower half of the screen, swap the same connectors on Y-Drive B. If after swapping the cables, the
stripe moves to the new screen position, replace the Ydrive. If the stripe stays in the same position, replace the
corresponding scan module. Don't forget to put the cables back in the original positions.
Models Covered: PDPV401, PDPV402
Tip Date: January 24 2001
The Tech Name: Jeff Andrews
Symptom: Dark pix (no luminance) on video or Y/C.
Cure: Solder bridge on R2851 Analog Video.
Models Covered: PDPV401, PDPV402
Tip Date: July 25 2000
The Tech Name: Bob Shoemaker
Symptom: Makes "chirping" sound every second. Shuts down after 10 seconds. Video is dark with lots of snow.
Cure: Found VCSP on sub -power board reading 3V. Should be 42V. Replaced sub-power board.
Models Covered: PDPV401, PDPV402
Tip Date: July 17 2000
The Tech Name: Bernie Shelton
Symptom: "Out of Range" displayed while in RGB mode.
Cure: Limit of video resolution is 640 X 480. Reset computer to lower resolution output.
Models Covered: PDPV400, PDPV401, PDPV402
Tip Date: July 12 2000
The Tech Name: Jeff Andrews