Whirlpool WVW51UC0HV Інструкція з монтажу та інструкція з експлуатації та догляду - Сторінка 7
Переглянути онлайн або завантажити pdf Інструкція з монтажу та інструкція з експлуатації та догляду для Вентиляційна витяжка Whirlpool WVW51UC0HV. Whirlpool WVW51UC0HV 9 сторінок. Wall‑mount canopy range hood
Також для Whirlpool WVW51UC0HV: Інструкція з монтажу; інформація про використання та догляд (28 сторінок)
- 1. Installation Requirements
- 2. Location Requirements
- 3. Tools and Parts
- 4. Product Dimensions
- 5. Venting Requirements
- 6. Electrical Requirements
- 7. Installation Instructions
- 8. Prepare Location
- 9. Install Range Hood
- 10. Connect Vent System
- 11. Make Electrical Connection
- 12. Install Vent Covers
- 13. Complete Installation
- 14. Range Hood Use
- 15. Range Hood Controls
Make Electrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box and install
a UL Listed or CSA approved 1/2" (12.7 mm) strain relief.
A. Terminal box
B. Knockout
C. Terminal box cover
4. Run home power supply cable through strain relief
into terminal box.
G
A. Home power supply cable
B. UL Listed or CSA
approved strain relief
C. UL Listed wire connectors
5. Use UL Listed wire connectors and connect
black wires (E) together.
C
B
A
A
B
C
D
E
F
D. White wires
E. Black wires
F. Green (or bare) and
yellow-green ground wires
G. Terminal box
6. Use UL Listed wire connectors and connect
white wires (C) together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
7. Connect green (or bare) ground wire from home power
supply to yellow-green ground wire (F) in terminal box
using UL Listed wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.
Install Vent Covers
NOTE: Remove protective film from the vent covers.
1. When using both upper and lower vent covers, push lower
cover down onto hood, and then lift upper cover to ceiling
and install with (2) 4.2 x 8 mm screws.
B
A
A. Bracket
B. 4.2 x 8 mm screws
C. Vent cover
NOTE: For vented installations the upper vent cover
may be reversed to hide slots.
C
9