INSTALLAZIONE
Eseguire in sequenza le seguenti operazioni :
configurare i jumper J11, J12 e LAUNCHING in funzione della modalità di attivazione della sirena;
collegare la batteria tampone da 12 V
collegare l'alimentazione esterna da 13,8 V
collegare la linea "positivo a mancare/dare" o "negativo a mancare/dare" al morsetto START;
i contatti antiapertura e antistrappo sono collegati in serie e devono essere connessi al relativo
circuito della centrale di allarme attraverso i contatti TAMPER;
regolare il trimmer per la temporizzazione del suono e lampeggio desiderati;
chiudere il contro-coperchio in metallo con le apposite viti;
chiudere la sirena con il coperchio in plastica.
ENGLISH
The SR135 is a high-power back-up battery siren (105 dB at 3m) protected against tampering (opening,
tearing off). It features a 10W flasher and a sound/flash timer, variable with adjustable trimmer from 1 min. to 7
min., which trips in case of prolonged alarm (eg. connection cable cutting). It has a first switch-on stop
function to prevent the siren from tripping during installation. (for enabling the siren for normal use it's
necessary to activate/deactivate alarm start).
TECHNICAL SPECIFICATIONS
Rated power voltage:
Operating limit voltages:
Amp draw at max power:
Amp draw when not operating:
Sound pressure (at Vn=12VDC):
Light power:
Sound and flash timer:
Buffer battery:
Dimensions:
Weight (with battery):
Operating temperature:
Flashing short-circuit protection fuse:
IP grade
ADJUSTMENTS AND CONNECTIONS
Trimmer TR1 : sound and flashing timer adjustment from 1' to 7' ± 20%
TAMPER terminals : contact N.C. resistant to opening and rip-off
SUPPLY terminals : 13.8 VDC power supply ( rated )
START terminal :
"positive missing"
"negative missing"
"Start with positive" Jumper J11=
"Start with negative"
"launching"
In the "launching" mode, the "+12v" terminal must be connected to the "start" terminal (no back-up battery)
IMPORTANT:
In the launching mode the siren starts howling as soon as power is supplied at the terminals "supply". In this
mode there is no first switch-on stop function.
2 Ah ai fili rosso e nero con faston.
Jumper J11=
Jumper J12=
Jumper LAUNCHING =
Jumper J11=
Jumper J12=
Jumper LAUNCHING =
Jumper J12=
Jumper LAUNCHING =
Connect a 10Kohm resistor between terminal "START" and terminal "-12V"
Jumper J11=
Jumper J12=
Jumper LAUNCHING =
Connect a 10Kohm resistor between terminal "START" and terminal "+12V"
Jumper J11=
Jumper J12=
Jumper LAUNCHING =
ai morsetti SUPPLY (**);
13.8 VDC
10 ÷ 15 VDC
1.5 A
2.5 mA
110 dB(A) at 3 m
10W
from 1' to 7' ± 20%
12 VDC , 2 Ah
236mm(L) x 280mm(H) x 99mm(P)
2700g
- 25 °C ÷ + 55 °C
2A
54
open
female jumper on B
female jumper on OFF
closed
female jumper on A
female jumper on OFF
open
female jumper on A
female jumper on OFF
open
female jumper on B
female jumper on OFF
open
female jumper on A
female jumper on ON