CONTINUOUS DRAINAGE
• Switch off the unit and remove the plug from the mains.
• Remove the water stopper and rubber plug.
• Connect a drain tube (ø 20 mm inner dimension) onto the water outlet and extend with
extra water tube if needed.
• Place the other end in a normal drain. Make sure that the tube is free from twists and bends.
The tube must decline over its entire length.
CLEANING
WARNING! First of all switch off the unit and remove the plug from the wall socket.
Clean the housing with a soft, damp cloth. Never use aggressive chemicals, petrol,
detergents or other cleansing solutions.
Clean the screen filter regularly with a vacuum cleaner. See also "air filter" section.
NOTE! Never use the air conditioner without the screen filter.
TROUBLE SHOOTING
Never try to repair or dismantle the air conditioner yourself. Incompetent repairs result in loss of
warranty and can endanger the user and the property.
Problem
The air
No power supply.
conditioner does
Is the LCD light fl ashing.
not function.
Timer function is active.
The air
In direct sunlight.
conditioner does
Windows or doors open, many
not seem to
people or a heat source in the room.
perform.
Dirty filter.
Air inlet or air outlet blocked.
Room temperature lower than the
selected value.
The unit is noisy. Unit stands uneven.
The compressor
The overheat protection is probably
does not work.
activated.
The remote
Distance too great.
control does not
Remote control signal not detected
function.
by the control panel.
The batteries are drained.
To correct problems that have not been described in the table and/or if the recommended solutions fail to solve the
problem, contact an authorized service centre.
10 0
Cause
Connect to a functioning outlet and switch on.
Empty the internal water container.
Deactivate TIMER function.
Close curtains.
Close doors and windows, place an extra air
conditioner.
Clean or replace the filter(s).
Remove the blockage.
Change temperature selection.
Place on an even, solid surface (less vibrations).
Wait 3 minutes until the temperature has
decreased, then turn on the unit again.
Make sure the remote control is correctly
aimed at the control panel.
Replace the batteries.
Solution