RELEASE THE REFIRGERANT
1
For the unit with recharging value, you can
discharge the refrigerant directly by the value.
2
For the unit without the value, please:
2.1
File the copper tube of the compressor.
* Do not file the copper tube off
completely, as long as there is an
opening is enough.
2.2
Use a tongs to clamp the copper tube,
the refrigerant will be released then.
Caution!
1. Whenever examine or replace the spare parts
of Cooling system, it is strictly necessary to
clean out the refrigerant
2. Never use air solder to solder the copper tube.
And to prevent from danger, please proceed the
releasing in a place with good ventilation and
away from fire.
3. If you need to repair or replace the parts of the
cooling system, please wait 10 minutes after the
refrigerant is released. Please use a soldering
iron to solder off the connection. *Please do not
use file to open the tubes, otherwise, the
system will be contaminated by small pieces of
metal.
4. As long as the tubes is opened, please use a
plastic film (such as plastic bag) to cover it
immediately. However, if you will not
re-assemble the parts in a short time, you
should use a plastic bag to cover its opening
instead, in order to keep it from contaminated
completely.
6