ELECTRICAL WIRING

The unit can be supplied with a cord and an earthed plug. If it ever becomes
necessary to replace this plug, be sure to use an earthed plug suitable for the power
supply in your area and conform your national safety standard.
The wires of the cable are coloured in accordance with the standard electrical code.
BLUE
NEUTRAL
BROWN
LIVE
/
GREEN
YELLOW
EARTH
The
) wire should be connected to the terminal in the plug marked N
(
BLUE
NEUTRAL
or coloured black.
The
) wire should be connected to the terminal in the plug marked L or
(
BROWN
LIVE
coloured red.
The
/
(
GREEN
YELLOW
marked E or coloured green or marked with this symbol
The unit must be connected to the power supply with the appropriate leads.
The cord should pass through holes with rubber grommets.
Properly fused disconnect switches must be installed between the unit and the
power source.
The unit must be wired with an isolation (mains) switch accessible from outside
the wet area in which the unit is installed, to comply with IEE regulations.
Attention! 3 minutes delay on all units with 'Alfa-14' controller.
When starting or restarting the unit, it will take 3 minutes before the compressor
and the fan will start running.
) wire should be connected to the terminal in the plug
EARTH
:
GB
3