Silent Disarm
Pressing button 1 immediately before button 2 is pressed will disarm the alarm system without beeping the
siren unit. All other features including the indicator flashes will remain the same. Note: If the alarm is giving the
driver a warning such four flash warning that the alarm has been triggered, the alarm system will beep the siren
even if it is overridden by the remote or the software switch. Fault warnings take priority over silent disarming.
Sensor Override Mode
Sensor's Warning Zone Override Mode
Pressing button 1 twice within 3 seconds at any time in armed stage will cause the pre warn zone of the shock
sensor and optional sensor (if installed) to disable. Two siren beeps and two indicator flashes will confirm the pre
warn zone of the sensor has been disabled.
Sensor Override Mode
Pressing button 1 twice within 3 seconds at any time while armed with pre warn zone of the sensor overridden
will cause the shock sensor and optional sensor (if installed) to completely disable. Three siren beeps and three
indicator flashes will confirm both the pre warn zone and the main trigger of the sensor has been disabled.
Sensor Re enable Mode
Pressing button 1 twice within 3 seconds at any time while armed with the sensor completely disabled will cause
the shock sensor and optional sensor (if installed) to re enable. One siren beep and one indicator flash will confirm
both the pre warn zone and the main trigger of the sensor has been reinstated.
NOTE: If you have armed the alarm system in the Silent mode, the respective numbers of the indicator flashes
will confirm the sensor override/re enable mode, but there will be no siren beeps.

Automatic Functions

Auto Re arming
This feature can be selected using programming.
The alarm system will re arm and re lock the doors 30 seconds after it has been disarmed unless the doors,
hood or trunk is opened or the ignition is switched on. This feature is to avoid accidental disarming of the alarm
system.
Quick Auto Rearming (User Authorization)
This feature can be selected using programming.
The alarm system includes a quick auto re arming procedure which will re arm the alarm system after 3
seconds unless the disarm authorisation button (buttons) is pressed. If the disarm authorisation button sequence is
not pressed within 3 seconds of disarming, the alarm system will automatically re arm and re lock the doors. If the
door/trunk/hood is opened or the ignition is turned on within 3 seconds of disarming without the disarm authorisation
button being pressed, the alarm system will immediately return to the armed condition and will then trigger.