Coastal WEATHERPAK EOC Handbuch für Betrieb und Wartung - Seite 12

Blättern Sie online oder laden Sie pdf Handbuch für Betrieb und Wartung für Wetterstation Coastal WEATHERPAK EOC herunter. Coastal WEATHERPAK EOC 17 Seiten.

Coastal WEATHERPAK EOC Handbuch für Betrieb und Wartung
Operating Temperature Range
Measuring Range
Output Scale
RH Accuracy
Temp Accuracy
2.4.3

Barometer (Optional)

The Barometer is housed in the WEATHERPAK
is processed. The system uses atmospheric pressure and site-specific constants to compute
altimeter setting. The sensor is a versatile electronic barometer featuring high accuracy, low
power, wide operating temperature range with RS-232 serial data I/O. An accuracy of ±0.3 hPa
rms is maintained over the entire specified operating pressure and temperature range.
Operating Temperature Range
Operating Pressure Ranges
Accuracy
2.5
WEATHERPAK
®
The WEATHERPAK
sensor, optional relative humidity sensor, compass, communications link, and power supply
circuitry in a sealed weatherproof enclosure. The WEATHERPAK
polling signals to the sensors and receives data signals from the sensors.
The compass automatically aligns to magnetic north. If placed laterally near a large mass of steel
or other magnetic material, an erroneous compass reading may result. (The top of a van is OK,
but next to it is not an ideal location). Try to place the WEATHERPAK
laterally from large vans, busses, cranes, etc.
®
2.5.1

ZENO

®
The ZENO
accepts and stores sensor data from the AT/RH sensor, barometer and wind sensor. It
also checks alarms and control functions (diagnostic inputs) including ZENO
monitor. Analog data are converted to serial digital data with low (12 bit, 10,000 samples/s, 2
channels maximum), high (15 bit, 10 samples/s), or ultra-high (18 bit, 2 samples/s) resolution.
®
The ZENO
Datalogger processes the sensor data in a 32-bit microcontroller and then sends the
processed sensor and other data in RS-232 serial format. The microcontroller allows extremely
P/N: 0302-117-004 Rev. 0
Table 2-2 – AT/RH Sensor Specification Data
-30 °C to +60 °C
0 to 100 %RH
0 ... 100 %RH equals 0 ... 1 VDC
+ 3%
+ 0.6°C
Table 2-3 – Barometer Specification Data
-40°C to +85°C
500 to 1200 hPa (mb)
+ 1mb at 22°C / + 3mb full range
®
EOC
EOC consists of a ZENO
WEATHERPAK
Operations & Maintenance Manual
®
EOC. The data is sent to the ZENO
®
Datalogger, optional barometer, temperature
®
EOC sends control and
®
EOC
®
where it
®
EOC at least 30 meters
®
Datalogger power
7