WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, PLEASE READ THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock the
service disconnecting means to prevent power from being switching on accidentally. If the service disconnecting means cannot
be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical
wiring must be done by a licensed person(s) in accordance with all applicable codes and standards, including fire-rated
construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue
(chimney) of fuel burning equipment to prevent backdraft. Follow the heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall or
ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit.
8. This unit must be grounded. 9. Never place a switch where it can be reached from a tub or shower. 10. Not for use in kitchens.
11. Install fan at least 2.5 m (8.2 feet) above the floor. 12. WARNING: To reduce the risk of fire or electric shock, do not use this
fan with any solid-state speed control device. 13. The fan must not be installed in a ceiling thermally insulated to a value greater
than R40.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up for wall
application.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall and construction dust away of motor unit.
4. Please read specification label on product for further information and requirements.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance, lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling.
OPERATION
Use an on/off switch to operate this fan. See "Connect Wiring" for details.
ASSEMBLY INSTRUCTIONS
MOUNT DIRECTLY TO JOIST OR I-JOIST
Place the housing assembly in the opening so the bottom edge
is flush with the finished ceiling. Nail the housing assembly to
the joist using nails.
POSITION THE HOUSING ASSEMBLY
Position the housing assembly against the joist. With a pencil, trace
an outline of the housing assembly onto the ceiling. Set the housing
aside, and cut out an opening for the fan.
IMPORTANT:
When the product is installed on the wall, the adaptor
should be facing upward.
MODEL: AP50-S
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner.