2. Turn CH2 CURRENT KNOB[4] clockwise to maximum current output, and then use CH1 CURRENT
KNOB[19] adjust the desired current output value.(Reference to Section 5.2)
3. Use CH1 VOLTAGE KNOB [18] to adjust the desired voltage output value.
4. Connect the circuit to the CH1 "+"TERMINAL [24] and CH2"-"TERMINAL [28] to get double voltage output.
5. For the bi-polar DC power supply with common ground, connect CH2 "+" TERMINAL [27] to "GND"
GROUNDING TERMINAL [26]. CH1 "+"TERMINAL [24] is the positive output and CH2 "-"TERMINAL [28] is
the negative output.

5.5 SETTING PARALLEL TRACKING MODE

1. Press both TRACKING MODE SLECTION KEY [12, 15] to enable parallel tracking mode .In parallel tracking
mode, CH2 output voltage and current value follows CH1 setting. The output current is double to the CH1
display value.
Illustration of Bi-Polar Tracking Mode
Illustration of Parallel Tracking Mode
13