1.3.4.3 Mode Recognition Pull-in
The monitor shall recognize preset modes within a
range of +/-1KHz whichever is less for horizontal ;
and within +/-1Hz for vertical.
1.3.4.4 User Display Modes
In addition to the factory pre-set video modes,
provisions shall be made to store up to 9 user
modes. If the current mode is a user mode, the
monitor shall select its previously stored settings.
If the user alters a setting, the new setting will be
stored in the same user mode. The user modes
are not affected by the pre-set command. If the
input signal requires a new user mode, storage of
the new format is automatically performed during
user adjustment of the display (if required).(
Please see Note.(4) )
Preset timing Chart
Preset Timing Chart
I tem
N o
Resoul ut ion
1
T103
640x480@60Hz
2
T173
640x480@72Hz
3
T109
640x480@75Hz
4
T182 [email protected]
5
T102
720x400@70Hz
6
T 104
800x600@56Hz
7
T 116
800x600@60Hz
8
T 117
800x600@72Hz
9
T 110
800x600@75Hz
10
T 108 832x624@74. 55Hz
11
T 118
1024x768@60Hz
12
T 157
1024x768@70Hz
13
T 141
1024x768@75Hz
14
T 203
1152x870@75Hz
15
T126
1152x864@75Hz
16
T161
1280x960@60Hz
17
T179 1280x1024@60Hz
18
T131 1280x1024@75Hz
19
T339
1280x720@60Hz
20
T213
1280x800@60Hz
21
T278
1366x768@60Hz
1.3.5 Controller Requirements
1.3.5.1 General Requirements
The monitor shall include a controller capable of
converting the analog RGB signal from a standard
SXGA resolution video controller in the CPU to a
signal which can be displayed on the panel. The
controller will include a PLL, A/D converters, LVDS
transmitter and other circuitry necessary to perform
its function. The PLL shall be stable enough to
ensure that a static image from the CPU is placed
in the same physical location on the flat panel in
each frame.
ACER X193HQ
6
Go to cover page
1.3.8 Display Communications Channel
The monitor assembly shall provide a display
communications channel that conforms to VESA
DDC2Bi hardware requirements. This configuration
shall contain the 128-byte EDID file as specified by
VESA EDID standard.The monitor should not write to
the EDID file for the first two minutes of operation
following power-up UNLESS some action taken by the
user or the host CPU forces the write (for instance,
requesting the serial number via the OSD).
Furthermore, it is recommended that CMOS switches
be incorporated to isolate the DDC IC from outside
connections while the EDID Fault Management is
being updated. This is to prevent corruption of the data
by attempts to read the data while it is being changed.
1.3.9 Firmware Update Function (same ISP function)
The update firmware need through from the D-Sub
connector, use DDC I2C bus to do update firmware.
1.4 PANEL ELECTRICAL
1.4.1 General Requirements
The panel used as the display device shall be an
WXGA 1366X768 resolution, 19 inch-wide TFT-LCD.
This panel shall be approved for use in this monitor.
1.4.2 Panel Timings
1. Product Specification (continued)
H-Sync
V-Sync
Band Width
Polarit
Source
(KHz)
(KHz)
(MHz)
H V
31. 469
59.941
25. 175
-
-
VESA
37. 861
72.809
31. 500
-
-
VESA
37. 500
75.000
31. 500
-
-
VESA
35
66.66
30.24
-
-
M AC
31.469
70. 087
28.322
-
+
VGA
35. 156
56. 250
36. 000
+ + VE SA
37. 879
60. 317
40. 000
+ + VE SA
48. 077
72. 188
50. 000
+ + VE SA
46. 875
75. 000
49. 500
+ + VE SA
49. 722
74. 55
57. 28
-
-
VE SA
48. 363
60. 004
65. 000
-
-
VE SA
56. 476
70. 069
75. 000
-
-
VE SA
60. 023
75. 029
78. 750
+ + VE SA
68. 700
75. 000
84. 520
-
-
67.5
75
108
+ +
60
60
108
+ + VESA
63.981
60.020
108.000
+ + VESA
79.976
75.025
135.000
+ + VESA
+ +
44.955
59.940
74.176
+ +
49.702
59.810
83.500
-
-
47.712
59.790
85.500
1. Product Specification (continued)
1.3.5.2 Video Stretching
The monitor shall contain provisions to "stretch" the
video signal, so that an input signal from the
computer in any resolution smaller than 1366 x
768 is automatically expanded to fill the entire
screen.
1.3.5.3 Panel Timing and Interface
The controller supplied with the monitor shall
control all panel timing. This controller shall
adequately insulate the monitor from the computer,
so that no possible combination of input signals
from the computer shall cause damage to the flat
panel or any other component of the monitor. The
LCD panel interface shall support the TFT
standard.
1.3.6 DC - AC Inverter Requirements
The DC-AC inverter is on the power board. The
frequencies used by the DC-AC inverter used to power the
backlight shall be chosen so as to prevent any noticeable
effects on the flat panel (such as a rolling effect).
1.3.7 Power Supply Requirements
The AC to DC converter power supply for the monitor shall
be an external AC to DC converter "brick" This brick shall
have an IEC receptacle for main power input and a pin - in
---socket for DC power out. The brick shall provide
sufficient power for both the monitor and the backlight
assembly, and shall meet requirements specified in Table
2.
Table 2. AC TO DC Converter Requirements
AC to DC Converter Requirements
The operating range shall be from 90 to 132 and 195 to 265 AVC
Input Voltage Range
sinusoidal for all models specified.
Input power frequency range sha;; be from 47. 5 to 63 Hz over the
Input Frequency Range
specified input voltage range.
Power consumption for the monitor shall be less than
Power Consumption
specified voltage and frequency ranges. In suspend or sleep mode
the power consumption will be less than 2W.
The AC input shall be fused and become electrically open as a result
Line Fuse
on an unsafe current level. The fuse many not be user replace
The power supply shall start and function properly when under full
Initial Cold Start
load, with worst case conditions of input voltage, input frequenct,
operating temperature, and cold backli ght lamps.
The inrush current must be limited to 30A when operated at
120VAC, and 50A when operated at 220VAC. Inrush current is
Inrush Current
measured at an ambient temperature of 25
temperature stabilized in the power
The power supply shall be damaged when switched ON for one
second and OFF for one second for seven consecutive after
Hot Start Cycl e
operating for one hour at full load, 25
voltage.
The power supply shall contain protectio
application of an input voltage below the minimum specified in this
Under Voltage
table shall not cause damage to the power supply unit nor cause
failure of the input.
The power supply shall o perate within IEC 801 - 4 (± 1KV) and IEC
Line Transient
801-5 (± 2KV) for the domestic U.S. version. The UPS power
supply shall operate and comply with CE mark.
The lamps shall extend a sufficient amount from
the edge of the light guide that sputtering over the
life of the lamps shall not cause degradation of the
luminance uniformity (such as non-illuminated
bands along the edges of the display).
1.4.4.2 Lamps Startup Time
The backlight lamps shall start about 2 sec of the
time the monitor power switch is pressed or the
monitor is restarted from a power - down mode
.The starting time shall stay about 2 sec. for the
minimum expected life of the lamps.
Test conditions are as follows :
Ambient Light ----------------------
Temperature--------------------------
Inactive Time -----------------------
1.4.5 Defects
1.4.5.1 Visual Inspection
The LCD panel shall be inspected with all pixels
set to white,black , red , green , and blue. The color
variation, brightness variation , and overall
appearance must not be perceived as poor quality
by Lite-On . Areas and / or parameters considered
questionable shall be subjected to detailed
measurements .
ACER X193HQ
Go to cover page
Table 2
30
W over the
able.
o C, with the unit
-off.
o C, and nominal input line
n circuitry such that the
< 1.0 lux
10
℃
> 24 hours
5