Technical Data

UDS 7
Measuring element
Piezoresistive pressure sensor with
internal stainless steel diaphragm
Measuring ranges
0... 1 bar to 0... 10 bar
0... 15 psi to 0... 150 psi absolute
pressure
0 ... 10 bar to 0 ... 600 bar
0 ... 150 psi to 0 ... 9000 psi
relative pressure
Display
4-digit dot-matrix display, green, digit height 5 mm
Switching outputs
Operating temperature
range
Media temperature
-25 ... +100°C / -13 ... +212 °F
range
Process connection
G ¼,
(fitting "A" without
G ½ front flush
adapter)
1/4" – 18 NPT
7/16 – 20 SAE
Protection system/class
Electrical connection
Auxiliary power
For further technical data and options please refer to the data sheets
6
UTS 7
Pt100 (class B) according to
DIN IEC 751
0 ... +100 °C to -30 ... +150 °C
+32 ... +212 °F to -22 ... +302 °F
2 x transistor switching output,
pnp NO/NC function (programmable),
adjustable switching time delay 0... 9.9 s
-10 ... +70°C / +14 ... +158 °F
-30 ... +150°C / -22 ... +302 °F
G ¼,
1/4" – 18 NPT
Nema 4X, IP65/III
Plug 5-pin, M 12x1
18...  32 V DC
Operating and display elements/Dimensions
approx
120
35
1
2
120
approx
48
approx
35
131
2
approx
48
Dimensions in mm
Dual pressure switch UDS7
14
LEDs (1)
AL
(yellow) – alarm
S1
(green) – switching point 1
S2
(green) – switching point 2
Membrane keys (2)
Dialog item "change to
value/to function",
12
acknowledge inputs
Change dialog
items/functions, change
numerical values
Dual temperature switch UTS7
17
12
*L0