Electrician
• The security lamp should be wired to its own light switch.
• Do not interconnect with other lights on the same switch.
• Earth connection must be required.
• Multiple (More than one) Muro fittings must not be wired to a separate sensor.
• Multiple Muro Fittings cannot be wired to a single switching point.
Understanding the controls
Adjusting the duration time: The length of time that remains switched on after activation can be adjusted from (10±5) seconds to (4±1)
minutes. Rotating the TIME knob + to - will reduce the duration time.
Note: Once the light has been triggered by the PIR sensor any subsequent detection will start the timed period again from the beginning.
Adjusting the LUX control level: The Lux control module has a built-in sensing device (photocell) that detects daylight and darkness. The
( ) position denotes that the floodlight can work at day and night, and the ( ) position only work at night. You can set to operate the unit
at the desired level by adjusting the LUX knob.
Adjusting the sensitivity: The sensitivity means the Maximum distance which PIR Sensor can be triggered by movement body. Turning
the SENS knob + to - will decrease the sensitivity.
Setting the controls
1. Put the Lux control knob to light ( ) position, turn the wall switch on and wait half a minute for the control circuit to stabilize. At this
stage ensure that the TIME control knob is set at minimum duration. The security lamp will now switch on and remain on for about 30
seconds (within 60 seconds).
2. Direct the sensor toward the desired area to be scanned by adjusting the elbow joint and swivel joint on the sensor arm.
3. Important: loosen all lock nuts and screws on sensor and lamp before making any adjustments.
4. Have another person move across the center of the area to be scanned and slowly adjust the angle of the sensor arm until the unit
sensors the presence of the moving person, causing the light to switch on.
5. Adjust time control to required setting.
6. To set the light level at which the lights will automatically switch "on" at night, turn the LUX control knob from daylight to night. If the
lamps are required to switch on earlier, e. g. Dusk, wait for the desired light level, then slowly turn the LUX control knob towards
daylight while someone walks across the center of the area to be detected. When the floodlights switch on, release the LUX control
knob. You may need to make further adjustments to achieve your ideal light level setting.
Change the Color Temperature
1. Unscrew the Fixing Cover Screws then remove the cover
2. Change the Color Temperature at back of the light
3. W: 5000K
4. NW: 4000K
5. WW: 3000K
6. Re-fit the cover.
7. Mount light onto the wall
Note:
-The lamp must be installed by professional electrician
-Ensure the power supply is switched off before fitting this product
3
4
29-31 Richland St. Kingsgrove. Sydney NSW 2208 Australia
Phone: 02 9554 9600 | Fax: 02 9554 9433
[email protected] | www.domuslighting.com
1
5
-Do not touch the lamp when in use
-Keep away from hot steam and corrosive gas
Installation Manual
2
6