DOMUS LINE IR WI-XD Installationshandbuch - Seite 5

Blättern Sie online oder laden Sie pdf Installationshandbuch für Zubehör DOMUS LINE IR WI-XD herunter. DOMUS LINE IR WI-XD 15 Seiten. Wireless infrared proximity sensor

INSTALLATION MANUAL

TECHNICAL DATA

- Maximum operating distance 8 metres.
- Battery mod. CR2450 (3V) lithium (Fig.1).

INSTALLATION:

Fix the bracket (A) in the required position using the screws (B)
supplied in the pack (Fig.2)
Check the operating distance according to the indications given in
the table in Fig.3
CAUTION: The sensor must not be installed near electromagnetic
or heat sources or exposed to direct sunlight.
A maximum of 7 IR WI-XD sensors can be applied to a single
X-Driver
COUPLING WITH STATIC LIGHT X-DRIVER WITH MODULE CM2-XD
(Fig.4):
- Press the X-Driver button (C) until the blue signalling LED comes
on and then press the IR WI-XD (D) button until the signalling LED
(E) remains on steady, then briefly press the button (D) again until
the signalling LED (E) flashes.
EN
COUPLING WITH DYNAMIC TW LIGHT X-DRIVER WITH MODULE
CM2-XDTW (Fig.5):
- Press the X-Driver button (C) until the blue signalling LED comes
on and then press the IR WI-XD (D) button until the signalling LED
(E) remains on steady, then briefly press the button (D) again twice
until the signalling LED flashes twice.
LIMIT SWITCH OPERATION x TW STATIC AND DYNAMIC LIGHT:
- Limit switch operation, when the unit door covers the sensor (F)
the luminaires connected to the X-DRIVER switch off, and vice versa
when opening the door they switch on.
To change the operation from LIMIT SWITCH to DIMMER SWITCH
briefly press button (D).
DIMMER SWITCH OPERATION x STATIC LIGHT:
- ON-OFF function: The luminaires connected to X-DRIVER are
switched on and off by briefly moving the hand in front of the
sensor (F).
- DIMMER and LEVEL MEMORY functions: Keeping the hand steady
in front of the sensor (F) it is possible to adjust the brightness of
the luminaires.
The selected brightness will be stored until the next reset (LEVEL
MEMORY).
To change the operation from DIMMER SWITCH to LIMIT SWITCH
briefly press button (D).