ELECTRICAL INSTALLATION INSTRUCTIONS
All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other
applicable codes.
WARNING:
When using electrical products, basic precautions should always be observed, including the following:
1. DANGER: RISK OF ELECTRIC SHOCK
Connect only to a circuit protected by a ground-fault circuit interrupter.
2. Grounding is required. The unit should be installed by a licensed electrician and grounded.
3. Install to permit access for servicing.
4. All building materials and wiring should be routed away from the pump body and heater (if equipped).
The whirlpool should be installed on a 120 vac, 15 amp dedicated circuit. The circuit should be hard-wired from the
electrical power supply panel. The circuit must be a three (3) wire circuit from the electrical supply panel. A grounded
neutral wire and a third wire, earth ground, are essential. Heater equipped models require a separate 15 amp maximum
GFCI circuit.
E LE CTR ICAL I NS TA L L A TI ON
1 2 0 VAC
GND .
753572-100
S E P A RA T E
15 G F C I
OUTL E T
ELECTRICAL DIAGRAM

READ AND FOLLOW ALL INSTRUCTIONS

W HIRL P OO L MO UNT ED
PU MP /M OT OR
(3)
AIR SW ITC H OR
W AL L TI ME R