American Standard CADET 3 FloWise 2832.128 Montageanleitung Pflege und Wartung - Seite 2

Blättern Sie online oder laden Sie pdf Montageanleitung Pflege und Wartung für Toiletten American Standard CADET 3 FloWise 2832.128 herunter. American Standard CADET 3 FloWise 2832.128 4 Seiten. Two-piece toilet

6
BOLT CAP
WASHER
NUT
INSTALL TOILET
a. Position toilet squarely to wall and, with a rocking
motion, press bowl down fully on wax ring and flange.
Alternately tighten nuts until toilet is firmly seated on floor.
!
DO NOT OVERTIGHTEN NUTS
OR BASE MAY BE DAMAGED!
b. Install caps on washers. (If necessary, cut bolt height
to size before installing caps.)
c. Smooth off the bead of sealant around base.
Remove excess sealant.
8
INSTALL TOILET SEAT Install toilet seat in accordance with manufacturer's directions.
9a
Before continuing, determine the type of water supply connecation you have from
the chart below and use the appropriate assembly parts required to properly
reconnect the water supply. DO NOT use plumber's putty to seal these fittings.
METAL / COPPER
METAL FLANGED
FLARED TUBING
TUBING
LOCK NUT
CONE
WASHER
COUPLING
NUT
WATER
SHUT-OFF
These parts must be used as
illustrated to insure water-tight
connection. Use of existing
coupling nut may result in
water leakage. Water supply
tube or pipe must extend at
least 1/2" inside threaded
shank of valve (does not
apply to flanged tubing).
CAUTION: DO NOT USE
CONE WASHER WITH
PLASTIC SUPPLY LINE.
WARNING: Do not use plumber's putty, pipe dope, or any other sealant on the water supply connection to this tank. If the connection
!
leaks after hand tightening, replace the supply line. If the connection continues to leak with the new supply line, replace the fill valve.
Warranty is void if any type of sealant is used on the water supply connection.
CLOSET FLANGE
CLOSET BOLT
CAUTION:
METAL SPIRAL
TUBING
LOCK NUT
LOCK NUT
EXISTING
EXISTING
WASHER
CONE
WASHER
EXISTING
COUPLING
COUPLING
NUT
NUT
WATER
WATER
SHUT-OFF
SHUT-OFF
Use existing
Use existing spiral
coupling nut
cone washer.
and washer.
Fluidmaster cone
washer may not
seal completely on
spiral type supply
line.
CAUTION: Overtightening of
LOCK NUT or COUPLING NUT
could result in breakage and
potential flooding.
7
For Tanks/Bowls using Speed Connect System
(Tank mounting bolts pre-installed).
TANK MTG.
BOLTS PRE-
INSTALLED
WASHER/
COMBO
INSTALL TANK
a. Install large rubber gasket over threaded
outlet on bottom of tank and lower tank
onto bowl so that tapered end of gasket
fits evenly into bowl water inlet opening,
and tank mounting bolts go through
mounting holes. Secure with metal
washer/nut combo.
b. With tank parallel to wall, alternately
tighten nuts until tank is snugged down
evenly against bowl surface.
*
USE INCLUDED TOOL, NUT DRIVER, OR DEEP SOCKET RACHET.
DO NOT OVERTIGHTEN NUTS MORE
THAN REQUIRED FOR A SNUG FIT!
9b
VINYL / BRAIDED
CONNECTOR
LOCK NUT
COUPLING
NUT
WATER
SHUT-OFF
Captive cone
washers already
included. No
additional washers
needed.
- 2 -
RUBBER
GASKET
NUT
!
CAUTION:
With correct washers in
place (see Step 9a),
tighten COUPLING NUT
1/4 turn beyond hand tight.
DO NOT OVERTIGHTEN.
7 30 9 2 8 - 10 0 Rev. Q