American Standard Town Square S 4216.823 Montageanleitung Pflege und Wartung - Seite 4

Blättern Sie online oder laden Sie pdf Montageanleitung Pflege und Wartung für Toiletten American Standard Town Square S 4216.823 herunter. American Standard Town Square S 4216.823 4 Seiten.

American Standard Town Square S 4216.823 Montageanleitung Pflege und Wartung
11
A
Adjust water level to level
indicated on tank by turning
water level adjustment knob to
move float cup up or down.
B
If bowl fails to siphon, an
adjustment may be required
with the lift chain. Simply
remove the bead chain from
the retainment clip and take
up slack on the chain, and
reinsert on lift rod. Make sure
the chain is not too taught.
PROBLEM
POSSIBLE CAUSE
Does not flush
a. Water supply valve closed.
b. Supply line blocked.
c. Flush valve chain too loose or disconnected.
d. Sand or debris lodged in water control.
Poor or sluggish flush
a. Bowl water level too low.
b. Supply valve partly closed.
c. Partially clogged trapway and/or drain pipe and/or vent.
d. Supply pressure too low.
Toilet leaks
a. Poor supply line connection.
b. Poor bowl to tank/floor connection.
Toilet does not shut off
a. Flush valve chain too tight, holding flush valve open.
b. Flush valve seat and/or flapper worn or deformed.
c. Sand or debris lodged in water control.
CARE AND CLEANING
When cleaning your toilet, wash it with mild, soapy water, rinse thoroughly with clear water and dry with a soft cloth. Avoid detergents,
disinfectants, or cleaning products in aerosol cans. NEVER use abrasive scouring powders or abrasive pads on your toilet seat. Some
bathroom chemicals and cosmetics may damage the seat's finish.
!
WARNING: Do not use in-tank cleaners. Products containing chlorine (calcium hypochlorite) can seriously damage fittings in the tank. This
damage can cause leakage and property damage.
American Standard shall not be responsible or liable for any tank fitting damage caused by the use of cleaners containing chlorine
(calcium hypochlorite).
In the United States:
American Standard Brands
1 Centennial Ave.
Piscataway, New Jersey 08854
Attention: Director of Customer Care
For residents of the United States, warranty
information may also be obtained by calling the
following toll free number: (800) 442-1902
www.americanstandard.com
Water Level
Adjustment Knob
Float Cup
Fill Valve
Or Water
Control
TROUBLESHOOTING GUIDE
In Canada:
LIXIL Canada, ULC
5900 Avebury Rd.
Mississauga, Ontario
Canada L5R 3M3
Toll Free: (800) 387-0369
www.americanstandard.ca
- 4 -
Trip Lever
Rod
Flush Valve
Chain
Overflow
Tube
Float
Flapper Seal
Flapper
Water Supply Line
CORRECTIVE ACTION
a. Open valve and allow water to fill tank.
b. Shut off water supply, disconnect supply line and inspect all gaskets and
washers. Reassemble. Also, see Fluidmaster maintenance at:
www.americanstandard-us.com/enews/fluidmasterguide.pdf
c. Readjust chain length as required.
d. Shut off water supply. Remove cap and clean as per Fluidmaster
maintenance instructions at:
www.americanstandard-us.com/enews/fluidmasterguide.pdf
a. Check that refill tube is connected to water control and inserted into tank
overflow without being kinked or damaged.
b. Open supply valve fully. Be sure that proper supply tube size is used.
c. Remove obstruction. Consult a plumber if necessary.
d. Normal supply pressure must be at least 20 psi.
a. Review Step 10 of installation procedure.
b. Review Step 1 through 9 of installation procedure.
a. Readjust chain length as needed. Review Step 11.
b. Shut off water supply. Replace flush valve.
c. Shut off water supply. Remove cap and clean as per Fluidmaster
maintenance instructions at:
www.americanstandard-us.com/enews/fluidmasterguide.pdf
American Standard B&K Mexico
Ecatepec 55540 Edo. Mexico
www.americanstandard.com.mx
Refill
Tube
Approximate
Water Level
Flush
Valve
Tank to Bowl Gasket
In Mexico:
S. de R.L. de C.V.
Via Morelos #330
Col. Santa Clara
Toll Free: 01-800-839-1200
73 0 23 5 4- 10 0 Rev. A 4 /18