American Standard YORKVILLE VORMAX Einbauanleitung - Seite 2
Blättern Sie online oder laden Sie pdf Einbauanleitung für Toiletten American Standard YORKVILLE VORMAX herunter. American Standard YORKVILLE VORMAX 4 Seiten. Back outlet toilet
3
INSTALL NEOPRENE OR GRAPHITE FELT SEAL*
Install seal evenly around waste flange (horn).
Apply a thin bead of sealant around base flange.
* Note: Wax seal not recommended for this application.
5
INSTALL TOILET
a. Position toilet squarely to wall and, with a rocking motion,
push bowl against ring and flange. Alternately tighten nuts
until toilet is firmly anchored.
CAUTION: DO NOT OVERTIGHTEN NUTS
!
OR BASE MAY BE DAMAGED!
b. Insert the tapered washers (supplied in the kit) into the lag
bolts (not supplied). Insert bolts through mounting holes
and tighten into pre-drilled floor openings.
c. Install the four bolt caps on tapered washers. (If necessary,
cut wall bolt length to size before installing caps.)
d. Smooth off the bead of sealant around base.
Remove excess sealant.
6
Connect water supply line.
(Sold separately)
Hand tighten nut.
GASKETS
Confirm gaskets are fully seated on tank.
WARNING: Overtightening of water supply line nuts could result in breakage and potential flooding. If the connection leaks after hand tightening,
!
replace the supply line. Do not use any type of sealant on the water supply connection. Use of plumber's putty, pipe dope, or any other type of
sealant will void the warranty.
WARNING: Do not use plumber's putty, pipe dope, or any other sealant on the water supply connection to this tank. If the connection leaks after
!
hand tightening, replace the supply line. If the connection continues to leak with the new supply line, replace the fill valve. Warranty is void if any
type of sealant is used on the water supply connection.
SEALANT
NEOPRENE
SEAL
7
Carefully place tank
over bowl then tighten
handles alternately
until the tank contacts
the front and back of
bowl achieving
china-to-china contact.
4
INSTALL TOILET ON FLANGE
a. Unplug waste opening and install toilet on closet flange so bolts
project through mounting holes.
b. Loosely install retainer washers and nuts. Side of washers marked
"THIS SIDE UP" must face up!
LAG
BOLT
TAPERED
WASHERS
BOLT
CAP
NUT & WASHER
BOLT
CAP
BOLT
HEAD
WASHER
8
Securely
connect water
supply line to
Shut Off
Valve.
- 2 -
FLANGE
FLANGE BOLTS
Turn on
water
supply.
7302407-100