Installer setup

Follow the procedure below to configure the Comfort Control to match the
installed heating/cooling system, and customize feature operation as desired.
To begin, press and hold the
buttons until the display changes
Setup Function
1
System type
3
Fan control
(heating)
5
Heating cycle rate
(CPH: cycles/hour)
9
Compressor
cycle rate (CPH)
12
System setting
adjustment
13
Adaptive Intelligent
Recovery™
14
Temperature
display
15
Compressor
protection
16
Schedule format
27
Heat temperature
range stops
28
Cool temperature
range stops
31
Dehumidification
Control
and
FAN
Settings & Options
0 Gas, oil or electric heat with air conditioning
1 Heat pump
2 Heat only (2-wire systems/power to open & close zone valves/
normally open zone valves)
3 Heat only with fan
4 Cool only
0 Gas or oil furnace — equipment controls fan in heating
1 Electric furnace — Comfort Control controls fan in heating
5 For gas or oil furnaces of less than 90% efficiency
1 For steam or gravity systems
3 For hot water systems & furnaces of over 90% efficiency
9 For electric furnaces
[Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH]
3 Recommended for most compressors
[Other cycle rate options: 1, 2, 4, 5 or 6 CPH]
0 Manual changeover (Heat/Cool/Off)
1 Auto changeover (Heat/Cool/Auto/Off) **See page 10
2 Auto changeover only (Auto) **See page 10
1 On **See page 9
0 Off
0 Fahrenheit
1 Celsius
5 Five-minute compressor off time **See page 9
[Other options: 0, 1, 2, 3 or 4-minute off time]
0 5/2 (programmable weekdays and weekends)
1 5/1/1 (weekdays, Saturday & Sunday programmable)
90
Highest heating temperature setting
40-89 Heating temperature range (increments of 1°F, or 0.5°C)
60
Lowest cooling temperature setting
61-99 Cooling temperature range (increments of 1°F, or 0.5°C)
1 Cooling Droop
2 Cooling Droop with Comfort-R
3 Cooling Droop with Comfort-R
0 None
Function
number
Done
Press
or
Press
NEXT
Press
DONE
(15 seconds Fan Delay)
TM
TM
(30 seconds Fan Delay)
7
Setting
Next
to change settings
to advance to next function
to exit and save settings