INSTALLING THE UPPER LIMIT CAM

STEP 1: To install the upper limit cam, run the lift down about
1 foot by using the control on the armrest.
STEP 2: Locate the upper limit cam and move to the top of
the track - position it approximately ½" from top track cover
and tighten into place.
STEP 3: Final Limit Switch Actuator In the event that the
lift over travels or is moved up past the normal upper stop
position, the lift will push the final limit actuator up into the
final limit switch disabling the unit. In order to return the lift
to operation, you must manually hand crank the lift down the track a few inches, and then
slide the final limit actuator down approximately one inch by tapping on it.

INSTALLING THE CALL CONTROLS

Upper call control box
Lower call control box
Rubex Stair Lift Install Manual | www.Ameriglide.com | 866-378-6648
14 //
16
STEP 1: Finish routing the call control wire into the upper
track channel on the wall side of the track. Plug into one of
the two call control connectors.
STEP 2: Plug in the upper call control box to a call control
connector.
STEP 3: Plug in the lower call control box to the call
control connector at the bottom of the track.
NOTE: Call controls can be mounted to the
floor so they can be operated by your foot,
or placed on the wall and operated by hand.
Run the unit down to a few inches past the
lowest track splice.