Please Note: Due to the complexity of different building methods Astor
Bannerman do not supply installation fixings and anchors.
Important: The attachment rail is the main load bearing fixing; it is vital that it is
•
Measure 100mm up from the floor along the centre-line of the final position of the unit; using a
spirit level, draw a horizontal line, either side of the centre line, at least 50mm long.
•
Place the attachment rail with the open lip upwards, on the line . With a pencil mark two of the
holes for the rail at least 50mm apart.
•
Using a 6mm masonry bit, drill two full depth pilot holes at the marked positions and then open
up in order to accept the anchor fixings.
•
Fix the attachment rail, with the open lip uppermost onto the wall using two suitable fixings.
Ensure that the rail is level using a spirit level (adjust to suit) and check that it is secure.
•
With assistance, place the rise and fall unit onto the wall ensuring that the two short rails welded
to the unit engage with the one on the wall.
•
Ensure that the unit is level, then mark the wall through the remaining three attachment points,
two on the lower horizontal beam and one on the upper horizontal beam.
•
Remove the unit from the wall and at the three marked positions drill three 6mm full-depth pilot
holes.
•
Open the two to accept Anchor fixings. Open the upper hole to 10mm to accept a plastic wall
plug.
•
Fit the fixings and the plug into the wall.
•
Place the rise and fall unit back onto the wall-mounted rail. Fully fix the rise and fall unit to the
wall using suitable fixings.
Ensure that the mains supply to the junction box on the wall is switched OFF.
•
Electrically connect the rise and fall unit to the fused outlet behind the unit using the three-core
cable supplied. Ensure there is sufficient cable to allow the unit to rise and fall.
Ensure the handset is fitted BEFORE switching the power on.
•
•
Switch on the mains voltage, a light fitted next to the Handset socket on the right hand side of
the unit, should be illuminated.
secured correctly.