Door-Gard 2000e Installation und Programmierung - Seite 5

Blättern Sie online oder laden Sie pdf Installation und Programmierung für Tastenfeld Door-Gard 2000e herunter. Door-Gard 2000e 7 Seiten.

Door-Gard 2000e Installation und Programmierung
2000e & 2000eM Keypad Installation & Programming
Assigning Virtual Outputs to Physical Outputs
(Standalone Mode Only)
The keypad is equipped with nineteen Virtual Outputs and twelve
Physical Outputs. Virtual Outputs are functions that you can assign to
operate any Physical Output. Physical Outputs include the main relay
and aux relay on the keypad, the eight relays on the 2000-8EX Output
Module, and the two audio alerts on the keypad.
● Using Command 10, you can assign any Virtual Output to any
Physical Output or disable a Physical Output.
● Each Physical Output can have multiple Virtual Outputs
assigned to it.

Assigning Outputs

(Standalone Mode Only)
Command/Action
Assign Outputs
Virtual Outputs
1 – Lock Output
2 – Alarm Shunt
3 – Propped Door
4 – Forced Door
5 – OUT2
6 – OUT3
7 – OUT4
8 – OUT5
9 – OUT6
10 – OUT7
11 – OUT8
12 – OUT9
13 – OUT10
14 – Duress Output
15 – Panic Output (see page 5)
16 – Keypad Active Output
17 – Doorbell Output*
18 – REX Input Active
19 – Door Loop Input Active
*Note: The Doorbell Output also works in both Front End Modes.
Disable Virtual Output
Disable Physical Output
Programming the REX/Door
Loop Outputs (Lock, OUT2-10)
Note: The default output settings are:
● Lock Output = Main Relay
● Alarm Shunt = Aux Relay
● Forced Door = Audio Alert 1
● Propped Door = Audio Alert 2.
6-104402 X2
Keys to Enter/Details
10 # virtual output # physical
output # ✱ ✱
Physical Outputs
1 – Main Relay
2 – Aux Relay
3 – External Relay 1
4 – External Relay 2
5 – External Relay 3
6 – External Relay 4
7 – External Relay 5
8 – External Relay 6
9 – External Relay 7
10 – External Relay 8
11 – Audio Alert 1
12 – Audio Alert 2
Note: The keypad is equipped
with only two relays. The Output
Expansion Module (2000-8EX)
is required to use additional
outputs.
10 # virtual output # 0 # ✱ ✱
10 # 0 # physical output # ✱ ✱
49 # outputs # input # ✱ ✱
Outputs: Lock =1, OUT2 = 2,
OUT3 = 3, OUT4 = 4, etc
Input: REX = 0; Door Loop = 1)
Programming Output Times
(Standalone Mode Only)
Command/Action
Change Lock Output Time
Set OUT2 Time Duration
Set OUT3 Time Duration
Set OUT4 Time Duration
Set OUT5 Time Duration
Set OUT6 Time Duration
Set OUT7 Time Duration
Set OUT8 Time Duration
Set OUT9 Time Duration
Set OUT10 Time Duration
Set Propped Door Time
Set Forced Door Time
Note:
● OUT2-10: ttt = time units, mmm = multiplier.
Example: "12 # 2 # 5 # ✱ ✱" = 10 seconds
(2 time units multiplied by 5 seconds = 10 seconds).
● The maximum value of ttt and mmm is 255 (255 x 255).
● The default output times (Lock Output, OUT2-10) are 5 seconds.
● To toggle the output enter 0 for both ttt and mmm
Example: 12 # 0 # 0 # ✱ ✱.

Programming Keypad Options

(Default settings are in bold)
Command/Action
Change Keypad Options
Option
0 – Audio Keypress Feedback
1 – Visual Keypress Feedback
2 – Auto Entry
3 – Error Lockout
4 – User Lockout
5 – Two-Part Users
6 – Keypad Backlighting
7 – Keypad Backlight Dimming
8 – REX Processing Select
9 – Red LED Dimming
10 – Door Loop Output Processing
16 – Secured Series In/Out
18 – 8-Bit Burst Output
19 – WFE Red LED Select
20 – WFE Red LED Active State
21 – WFE Green LED Select
22 – WFE Green LED Active State
Note: WFE means Wiegand Front End
Keys to Enter/Details
11 # time # 0 # ✱ ✱ (1-255 sec)
12 # ttt # mmm # ✱ ✱
13 # ttt # mmm # ✱ ✱
14 # ttt # mmm # ✱ ✱
15 # ttt # mmm # ✱ ✱
16 # ttt # mmm # ✱ ✱
17 # ttt # mmm # ✱ ✱
18 # ttt # mmm # ✱ ✱
19 # ttt # mmm # ✱ ✱
110 # ttt # mmm # ✱ ✱
44 # time # 0 # ✱ ✱ (10-990 sec)
45 # time # 0 # ✱ ✱ (10-990 sec)
Keys to Enter/Details
30 # option # setting # **
Setting
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
0 = Only when
1 = Always
door closed
0 = Off when
1 = Always On
backlighting dim
0 = Not when
1 = Always
lock latched
0 = Records IN
1 = Records Out
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
0 = Low
1 = High
0 = Disabled
1 = Enabled
0 = Low
1 = High
5