DAB PUMPS LEADER ECOPLUS Series Anleitung für Installation und Wartung - Seite 9
Blättern Sie online oder laden Sie pdf Anleitung für Installation und Wartung für Water Pump DAB PUMPS LEADER ECOPLUS Series herunter. DAB PUMPS LEADER ECOPLUS Series 10 Seiten.
Electronic boosters with electronic safety device
FAULT
1. The red LED Flashes
2. The red LED stays on
3.The pump continuously
stops and starts
4. The pump does not work The pump is faulty.
6.
DISPOSAL
This product or its parts must be disposed of in accordance with the laws regarding the environment;
Use the local, public or private, refuse collection services.
7.
GUARANTEE
Any material or manufacturing defects will be corrected during the guarantee period established by current
law in the country where the product is purchased. It is up to the manufacturer to decide whether to repair or
replace any faulty parts.
The manufacturers guarantee covers all substantial defects attributable to manufacturing or material detects,
providing the product has been used correctly and in compliance with the instnictions.
The guarantee becomes null and void in the event of the following:
- unauthorized attempts to repair the appliance;
- unauthorized technical changes to the appliance;
· use of non-original spare parts;
- manhandling;
- inappropriate use. e.g. for industrial purposes.
The guarantee does not cover:
- parts liable to rapid wear and tear.
For any action under guarantee, contact an authorized customer support service, presenting your receipt for
the purchase ofthe product.
The manufacturer accepts no liability for any inaccuracies in the present booklet due to printing or copying
errors. The manufacturer reserves the right to make any changes to the product he deems necessary or
useful, without affecting its essential features.
CAUSE
Lack of water
Automatic reset attempts exceeded Disconnect and reconnect the power supply.
Automatic reset
1)the system is not air tight
2) Possible presence of foreign
objects inside the device.
The electronic device may be
blocked with limescale.
SOLUTION
Re-establish the regular flow of water.
1)Check the system and the pump connection.
2) Disconnect the pump, dismantle the pumps
electronic device and carefully rinse it buy
spraying water in the inlet – with a garden hose for
example.
After having disconnected the electronic device
from the pump, try running the pump on its own
connecting it to the mains. If the pump runs
correctly, check through the outlet that the
impellers inside the electronic device are
turning freely.
lf the impellers do not turn freely, clean the
electronic device by filling it with vinegar or
another descaler through the outlet. If the
impeller is free, contact the service centre.
6