7.3.
Site of installation of the PULSAR DRY
•
A solid anchoring of the pump to its support base helps absorb any vibrations created by
pump operation.
•
Block the pipes with their own supports and connect them so that they do not exert strain,
stress or vibration on the pump inlets.
•
It is always good practice to position the pump as close as possible to the liquid to be
pumped.
•
It is recommended to fit a foot valve on intake. To avoid the formation of air pockets in the
suction pipe, ensure that the suction pipe is tilted slightly towards the electropump.
•
Provide a hole for priming the pump in the delivery pipe (see paragraph. 9.1).
7.4.
Working conditions of the PULSAR DRY
•
Water temperature: from 0°C to + 40°C.
•
The electropump cannot operate when dry.
•
Install in vertical position.
•
If installed in a pit, the pit must be free from frost.
PULSAR DRY
installation
filter
non return
valve
below
head
installation
on intake
ENGLISH
Fig. 2
23
vent
pipe
supports
non return
valve
filling
cap
drainage
cap
pipe
supports
system
drainage
foot
valve
filter