Table 6.2.2. Parameters of the DCUH-3 programming menu
Message
1. UH
2. UC
3. Hd
4. AF
5. dL
6. Ar
7. CXX
8. SXX
9. EXX
10. SL
11.Sb
12. Gd
13. rS (1)
Item 1 is available until the service mode is reset.
Items 1–6 refer to main programming menu while items
7–13 — to advanced programming menu.
6.3. TO EXIT THE PROGRAMMING MODE
The device automatically exits the programming mode and
saves the changed values after setting the parameter of
6.4. PROGRAMMING OF DOCK LEVELER AND SECTIONAL DOOR OPERATION
There are three variants of operation of dock leveler and
sectional door.
Variant 1. Dock leveler
ing is OFF.
Set the following values for parameters 5 and 6 in pro-
gramming menu (see table 6.2.2):
 choose n value for parameter 5;
 choose n value for parameter 6.
Variant 2. Dock leveler
ing is OFF.
Set the following values for parameters 5 and 6 in pro-
gramming menu (see table 6.2.2):
 choose n value for parameter 5;
10
 choose Y value for parameter 6.
Setting option
Parameter value 1–9 — 3–11 sec.
Default value — 7 sec.
Change of value by 1 equals 1 sec.
Parameter value 1–9 — 5–21 sec.
Default value — 13 sec.
Change of value by 1 equals 2 sec.
Parameter value 1–9 — 2,5–6,5 sec.
Default value — 4,5 sec.
Change of value by 1 equals 0,5 sec.
Parameter value 1–9
(Y/n), default value — n
(Y/n), default value — Y
(0–99)
(0–99)
0–99
(Y/n), default value — Y
Parameter value 1–9 — 17–35 sec.
Default value — 25 sec.
Change of value by 1 equals 2 sec.
Parameter value 1–9 — 2–18 sec.
Default value — 10 sec.
Change of value by 1 equals 2 sec.
(Y/n), default value — n
parking is OFF, door
auto
parking is ON, door
auto
Time period in which hydro station motor stops during leveler
Maximum leveler lowering time in auto parking mode
Leveler raising time at the last stage of parking
Operating threshold of the leveler stop function during leveler
Automatic closing of the door after the leveler is parked
Activation of auto parking function
Indication of the last equipment failure:
E00 — no equipment failures during the whole period of operation;
E03 — short circuit in hydraulic station motor winding;
E04 — short circuit on control and display board
Inflatable dock shelter operation
Deflating time of the dock shelter
Time of automatic closing of the door after the leveler is parked
Navigation through the menu is carried out by the RAISE and
P buttons. RAISE button is used to switch between the pa-
rameters, and P button changes the value of the parameter.
the last menu item and pressing the RAISE button.
Variant 3. Dock leveler
ing is ON.
clos-
Set the following values for parameters 5 and 6 in pro-
auto
gramming menu (see table 6.2.2):
 choose Y value for parameter 5;
 choose Y value for parameter 6.
clos-
auto
Description
raising
raising mode only
Cycles counter / 1000
Service counter
E01 — usage error;
Reset of service mode
parking is ON, door
auto
clos-