Astralpool 25462 Handbuch für Installation und Wartung - Seite 5

Blättern Sie online oder laden Sie pdf Handbuch für Installation und Wartung für Water Pump Astralpool 25462 herunter. Astralpool 25462 16 Seiten. Self-priming pump for pools

Astralpool 25462 Handbuch für Installation und Wartung

1. GENERAL SAFETY WARNINGS

These symbols (
relevant warnings.
HAZARD. Risk of electrocution.
Disregarding this warning entails the risk of electrocution.
HAZARD.
Disregarding this warning entails the risk of harming people or damaging objects.
IMPORTANT.
Disregarding this warning entails the risk of damaging the pump or the installation.

2. INSTALLATION

2.1 SELECTING A LOCATION

The pump must be installed:
• Before the filter, heating system and/or water treatment unit.
• At a distance of 2 meters from the edge of the pool, to prevent water from splashing the unit. Some
standards allow other distances. Consult the standards in force in the country of installation.
• Ideally, 30 cm below the water level.
• Outside an area susceptible to flooding or on a stand with drainage.
• In a well ventilated place, to allow the pump to cool.
• There must be easy access for maintenance work on the device.
• It is recommended to leave space between the pump and the outer edges of the installation as
shown in the diagram (FIGURE 1).
• Place it on a stable, leveled and solid surface (e.g., concrete base).
• Fasten the pump to the ground using the anchoring stud so that it is suitably fitted in place. (FIGURE 2).
0.1 m
FIGURE 1
Installation and general maintenance manual
) mean that there is a potential hazard as a result of not heeding the
- SELF-PRIMING POOL PUMPS
Anchoring points
(On each side of the pump)
FIGURE 2