Astrapool Viron Series Installations- und Betriebsanleitung - Seite 10

Blättern Sie online oder laden Sie pdf Installations- und Betriebsanleitung für Water Filtration Systems Astrapool Viron Series herunter. Astrapool Viron Series 14 Seiten. Salt chlorinator

6.6 ACID Handling

Hydrochloric Acid should be handled with extreme care. Refer to Material Safety Data Sheets on Hydrochloric Acid. Do not
inhale Acid fumes. Do not spill and handle with extreme care during transport. Use protective gloves and goggles.
In the case of spillage wash down with fresh water immediately. Keep out of reach of children.
6.7 CHLORINATOR MAINTENANCE AND TROUBLESHOOTING
If the supply cord is damaged, it must be replaced by Astralpool or its service agent or a similarly qualified person in order to
avoid a hazard.

Cell Maintenance

Your Viron Chlorinator has an automatic cleaning feature that under normal conditions, will keep the cell plates clear of
deposits of salt and calcium.
Viron Series cells have a positive charge sensor that monitors the flow and salt levels of the water. This sensor is designed to
be fail safe. DO NOT ATTEMPT TO ABRASIVELY CLEAN THE FLOW SENSOR, THE FLOW SENSOR IS COATED WITH
SPECIAL RARE EARTH MATERIAL AND IF DAMAGED FROM ABRUSIVE CLEANING BY REMOVAL OF THIS COATING
WILL RESULT IN CORRUSION TO THE SENSOR PLEASE REFER TO BELOW "CELL CLEANING INSTRUCTIONS"
DAMAGE TO THE SURFACE OF THE FLOW SENSOR FROM INCORRECT CLEANING WILL NOT BE COVERED BY
WARRANTY
Cell Cleaning Instructions:
close applicable valves
-
-
disconnect the Chlorinator from the Mains by removing the 3 pin plug
-
disconnect the cell wires
undo the barrel nuts connecting the cell to your filtration system
-
turn the cell upside down (inlet and outlet on top) and fill the cell with a mix of 1 part Hydrochloric acid to 10
-
parts water and leave standing for a few minutes. As an alternative, you may use an approved commercial Cell
cleaning solution
repeat if necessary and then rinse well in clean water
-
do not abrasively clean the Flow Sensor to clean, ensure flow sensor surface is not damage. Damage to the
-
surface or removal of the coating from abrasive cleaning of the flow sensor will not be covered by warranty
re-install the cell ensuring o-rings are correctly located and barrel nuts are tightened to prevent leaks
-
re-connect cell wires with wing nuts supplied making sure the blue wire is connected to the blue terminal
-
Incorrect connection may damage your chlorinator control. Tighten wing-nuts to ensure the electrical
connection is sound
Return all valves to their normal positions, re connect power to the Chlorinator and turn on at power point.
-
WARNING: Follow safety instructions provided with the Hydrochloric acid or cleaning solution. When handling
Hydrochloric Acid, the use of eye protection, mask and gloves are highly recommended. Extreme caution should be
taken whenever handling Hydrochloric Acid or Cell Cleaning Solution.
Inst305 - Viron Series Chlorinator Instructions V05-17
10