FIELD WIRING

CAUTION: Label all wires prior to disconnec-
tion when servicing controls. Wiring errors
can cause improper and dangerous operation.
Verify proper operation after servicing.
Refer to Figure 10 for the wiring schematic
for these fireplaces.
This fireplace is completely wired internally.
On the right hand side of the fireplace, at the
rear, are four (4) wires required to connect the
Battery and switch for operation.
Two brown wires are for the connection of the
switch. These are labeled SW and SW. A black
and red pair are for connection to the battery
pack. These are labeled (+) and (–).
These wires are for low voltage current. An
electrical box has been provided to contain both
the switch and battery pack. Mount the box in
an appropriate location within the length of the
wiring provided. Feed all four wires through one
of the lower inlets to the box. Connect the switch
wires to the switch and the corresponding (+),
(–) to the battery holder.
Install two D-cell batteries (not provided) and
test the switch before closing the switch box
(refer to Figure 11). The igniter should spark
to the pilot when the switch is on.
10
ELECTRONIC IGNITION WIRING DIAGRAM
NOTES:
1. If any of the original wire as supplied must be replaced, use Type AWM 105°C - 18 gage wire ONLY.
2. Electrical Rating: 3V DC.
CAUTION: label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper operation after servicing.
WALL SWITCH BOX
WEATHER
SEAL
COVER
D-CELL BATTERIES
REMOTE WALL SWITCH
BLACK
WALL SWITCH BOX
BATTERY
REMOTE
WALL
SWITCH
RED
BROWN
BROWN
Figure 1
0
Weather Seal
Cover
Switch
Figure 1
1
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
PILOT BURNER
IGNITER-SENSOR
ASSEMBLY
IGNITER MODULE - 3V
BLACK
SPARK WIRE CABLE
BLACK
PILOT SENSOR CABLE
ELECTRONIC GAS CONTROL VALVE - DEXEN
ORANGE
(THTP)
(TP)
BLACK
LO
HIGH LIMIT
(TH)
SWITCH
GREEN
BLACK JUMPER
Schematic Representation Only
UMBILICAL CORD (9 Feet)
Orient Batteries Vertically
To Fit Within Box
IGNITER
FLAME
SENSOR
ROD
PILOT TUBE
HI