Ametek Sorensen DLM600 M6 Handbuch Addendum - Seite 3

Blättern Sie online oder laden Sie pdf Handbuch Addendum für Stromversorgung Ametek Sorensen DLM600 M6 herunter. Ametek Sorensen DLM600 M6 15 Seiten. Option for m9g, m130 or m131

1.1 INTRODUCTION
1.1.1 M6 with GPIB M9G
The option M6, herein, will describe the operation and M9G remote programming option
for the DLM600 series power supply with an Isolation and Polarity Reversal Relay PCB.
This option is assembled as a self-contained unit with newly designed extended lower
plate and top covers, which allow the user full isolation and reverse polarity capability
for both output and external sense. These units measure 21 inches from the tip of the
front panel controls to the rear panel output bars. They are about 8.5 inches wide and
1U tall. Illustrations of the DLM600's top, side, and rear views are shown on Pages 11
and 12 of this addendum.
1.1.2 M6 with Ethernet M130 and M131
This manual covers the M6 Option as it works in conjunction with M130 Remote
Programming Ethernet Option and the M131 Slave Option, for the DLM600 Series
power supplies. Specific information on M130 and M131 interface cards can be found in
the DLM Series M130/M131 Ethernet Option Programming Manual, P/N M362797-03.

1.2 FEATURES and FUNCTIONS

Transient Response Specification is 1400us
Depth is 20"
M9G - All standard features remain as described in the DLM600 Series manual and in
Section 1 of the M9 manual.
M130/M131 - Ethernet M130 and M131 features in manual, P/N M362797-03, apply.
1.2.1 Additional Features and Functions
-
Output voltage isolation from output load
Output local or remote
-
Output reverse polarity
-
-
Relay hot-switch lock-out (ensures that the voltage across the relay contacts
and the current through them, is near zero prior to changing relay states)
Relay automatically disconnects (relays automatically latch Open when a
-
shutdown occurs)
Addendum
1