Flying Industry Development CB-4 Benutzerhandbuch - Seite 2

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Fernsteuerung Flying Industry Development CB-4 herunter. Flying Industry Development CB-4 4 Seiten. Wireless remote control kit

1.1 Connect the positive pole of DC power supply to terminal "L / +" of INPUT, and connect the negative pole of DC power supply to terminal "N / -" of
INPUT.
1.2 Connect terminal B to the positive pole of DC power supply, connect terminal C to the positive pole of DC lamp, and connect the negative pole of
DC lamp to the negative pole of DC power supply.
2) If you want to control an AC 220V lamp, do as following:
2.1 Connect the positive pole of DC power supply to terminal "L / +" of INPUT, and connect the negative pole of DC power supply to terminal "N / -" of
INPUT.
2.2 Connect terminal B to the live wire of AC power supply, connect terminal C to one side of AC lamp, and connect another side of AC lamp to the
neutral wire of AC power supply.
Setting different control modes:
We have set the receiver as Self-locking control mode before delivery. If you want to use other control modes, do as following operation:
1) Setting Self-locking mode: Only connect Jumper-2.
Mode Self-locking (working with transmitter CB-4): Press -> On; Press again -> Off.
Press button A of the transmitter: The relay 1 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 1 is turned on.
Press button A again: The relay 1 is deactivated (disconnect the terminals B and C, connect the terminals A and B), and the lamp 1 is turned off.
Press button B of the transmitter: The relay 2 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 2 is turned on.
Press button B again: The relay 2 is deactivated (disconnect the terminals B and C, connect the terminals A and B), and the lamp 2 is turned off.
Press button C of the transmitter: The relay 3 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 3 is turned on.
Press button C again: The relay 3 is deactivated (disconnect the terminals B and C, connect the terminals A and B), and the lamp 3 is turned off.
Press button D of the transmitter: The relay 4 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 4 is turned on.
Press button D again: The relay 4 is deactivated (disconnect the terminals B and C, connect the terminals A and B), and the lamp 4 is turned off.
2) Setting Momentary mode: Only connect Jumper-1.
Mode Momentary (working with transmitter CB-4): Press and hold -> On; Release -> Off.
Press and hold button A of the transmitter: The relay 1 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 1
is turned on.
Release button A: The relay 1 is deactivated (disconnect the terminals B and C, connect the terminals A and B), and the lamp 1 is turned off.
Press and hold button B of the transmitter: The relay 2 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 2
is turned on.
Release button B: The relay 2 is deactivated (disconnect the terminals B and C, connect the terminals A and B), and the lamp 2 is turned off.
Press and hold button C of the transmitter: The relay 3 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 3
is turned on.
Release button C: The relay 3 is deactivated (disconnect the terminals B and C, connect the terminals A and B), and the lamp 3 is turned off.
Press and hold button D of the transmitter: The relay 4 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 4
is turned on.
Release button D: The relay 4 is deactivated (disconnect the terminals B and C, connect the terminals A and B), and the lamp 4 is turned off.
3) Setting Interlocking mode: Disconnect Jumper-1 and Jumper-2.
Mode Interlocking (working with transmitter CB-4): Press -> On; Press another button -> Off.
Press button A: Relay of the receiver 1 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 1 is turned on.
Relay of the receiver 2, 3, 4 are deactivated (disconnect the terminals B and C, connect the terminals A and B), other lamps are turned off.
Press button B: Relay of the receiver 2 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 2 is turned on.
Relay of the receiver 1, 3, 4 are deactivated (disconnect the terminals B and C, connect the terminals A and B), other lamps are turned off.
Press button C: Relay of the receiver 3 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 3 is turned on.
Relay of the receiver 1, 2, 4 are deactivated (disconnect the terminals B and C, connect the terminals A and B), other lamps are turned off.
Press button D: Relay of the receiver 4 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 4 is turned on.
Relay of the receiver 1, 2, 3 are deactivated (disconnect the terminals B and C, connect the terminals A and B), other lamps are turned off.
4) Setting Mixed mode (Momentary + Self-locking): Connect Jumper-1 and Jumper-2.
Mode Momentary for channel 1 & 2 (working with transmitter CB-4): Press and hold -> On; Release -> Off.
Press and hold button A of the transmitter: The relay 1 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 1
is turned on.
Release button A: The relay 1 is deactivated (disconnect the terminals B and C, connect the terminals A and B), and the lamp 1 is turned off.
Press and hold button B of the transmitter: The relay 2 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 2
is turned on.
Release button B: The relay 2 is deactivated (disconnect the terminals B and C, connect the terminals A and B), and the lamp 2 is turned off.
Mode Self-locking for channel 3 & 4 (working with transmitter CB-4): Press -> On; Press again -> Off.
Press button C of the transmitter: The relay 3 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 3 is turned on.
Press button C again: The relay 3 is deactivated (disconnect the terminals B and C, connect the terminals A and B), and the lamp 3 is turned off.
Press button D of the transmitter: The relay 4 is activated (connect the terminals B and C, disconnect the terminals A and B), and the lamp 4 is turned on.
Press button D again: The relay 4 is deactivated (disconnect the terminals B and C, connect the terminals A and B), and the lamp 4 is turned off.
How to pair the transmitter to the receiver:
1) Press the learning button of receiver for 1- 2 seconds; signal LED on the receiver is on. The receiver enters into status of LEARNING.
2) Press any one button on transmitter. If signal LED flashes quickly 15 times and turns off, it means learning is successful.