Coiltek CS-5000 V2 Betriebshandbuch - Seite 16

Blättern Sie online oder laden Sie pdf Betriebshandbuch für Zubehör Coiltek CS-5000 V2 herunter. Coiltek CS-5000 V2 20 Seiten.

Cable Connections

The two boards in the CS-5000 V2 and CS-5100 V2 controls are connected by nine-conductor cable.
The colored wires on each end of the cable are connected in the same order, the only difference being
that one end of the cable will have longer green and brown wires than the other. This end of the cable
will connect to the range card with the longer wires connecting to the LED mounted in the endcap of
the boom. Please follow the diagrams below to wire your unit.
Range Card & Endcap
Features of the CB-5101R-2 Range Card
This latest update of the Coiltek range card is form, fit and function compatible with the
CB-5101R, CB-5101R-1 versions (above). All installation procedures and precautions associated with
previous versions apply, including removal of the 7 pin connector (above).
The sensitivity potentiometer, which governs the amount of echo received, has been repositioned such
that adjustment may be made by removing the case end cap (figure below). On previous cards, this pot
was mounted flat so that adjustment required removing the card from the case or stand boom. Adjust
clockwise to increase sensitivity, counterclockwise to decrease.
14