Fluid
Service and Maint
It is recommended to run the machine on a monthly basis in order to achieve best
performance and output condition.
Excessive dust, liquid and dirt built up will degrade performance and cause overheating.
In an event of machine error, contact an authorized distributor/dealer for further technical
supports and service.
Red LED Indicator on the handle
Machine's Status
Ready to fog
Producing fog
Low battery
Machine error

Technical Specifications

- Input voltage
- Rated power
- Warm-up time
- Fluid consumption
- Fluid tank capacity
- Compatible fluid
- Ambient temp. range
- Control
- Dimension
- Weight
Use Air Guard FLD / FLV Antibacterial Solution for AG-20.
The machine is tested and calibrated with these authorized
fluids to achieve the best performance. Warranty will be
void, if any other type of liquid is used. Improper use of
liquid may lead to machine failure and danger.
LED Indicator
Constant on
Slow flash every 0.7 second
Quick flash every 0.3 second
Qucik flash every 0.1 second
DC 12V (Battery)
AC 100-240V, 50-60Hz (Battery charger)
600W
1 second (approx.)
14 ml/min
0.4 Liter (0.11 Gallon)
Air Guard FLD Antibacterial Solution
Air Guard FLV Antibacterial Solution
0 °C - 40 °C (32 °F-104 °F)
Manual, Timer, Radio Wireless Remote
L293 W108 H238 mm
(L11.54 W4.25 H9.37 inch)
8.5 kg (18.74 lbs)