Astromi.ch MGBox V2 Handbuch - Seite 12

Blättern Sie online oder laden Sie pdf Handbuch für Wetterstation Astromi.ch MGBox V2 herunter. Astromi.ch MGBox V2 14 Seiten.

Additionally, MGBox can also send information about calibration values stored in the EEPROM.
Standard Firmware:
$PCAL,P,0,T,0,H,0,MM,1,MG,0*69<cr><lf>
$
P
CAL
P
20
T
50
H
-10
MM
1
MG
0
*69

Setting, resetting, receiving Calibration data and other commands

In order to set, reset or query calibration data from the MGBox, similar formatted sentences can
be sent to the device. Please limit the commands to about 1 per second in order to give the
device time to respond to each command.

Setting pressure calibration

:calp,50*
:calp
50
*

Setting temperature calibration

:calt,22*
:calt
22
*

Setting humidity calibration

:calh,50*
:calh
50
*
Start of sentence
Proprietary sentence
Calibration data
Sensor type, pressure
Calibration value multiplied by 10, e.g. 2.0
hPa
Sensor type, temperature
Calibration value multiplied by 10, e.g. 5.0 °C
Sensory type, humidity
Calibration value multiplied by 10, e.g.
-1.0 %RH
MM: Send Meteo-Data to moun
Yes (0 = No)
MG: Send GPS-Data to mount
Disabled (1 = Enabled)
Checksum
Set calibration value for pressure
Calibration value multiplied by 10, e.g. 5.0
hPa
End of message indicator
Set calibration value for temperature
Calibration value multiplied by 10, e.g. 2.2 °C
End of message indicator
Set calibration value for humidity
Calibration value multiplied by 10, e.g. 5.0%
End of message indicator
Page 12
Version 1.3