Part VIII – Periodic Cleaning
Procedures
Cleaning and sanitizing schedules for your
dispenser are determined by your local Health
Department and / or Department of Agriculture
and must be followed accordingly. Check with
your local organization prior to determining your
cleaning schedule.
After determining your schedule, proceed as
follows:
Press the "OFF button"
On the front touch pad.
To drain the remaining liquid mix from the
dispenser, place a pail under the front drain plug
next to the front panel. Remove the front drain
plug, then slowly remove the hook drain plug
from inside the mix tank. The liquid mix will
now drain from the dispenser. Using the spatula
provided in the spare parts kit, direct the
remaining liquid mix to the drain hole in the mix
tank. Replace the hook drain plug into the mix
tank drain hole.
Fill the mix tank with 6 quarts of luke warm (80-
90F) water and a non-foaming dish washing
detergent solution. Press the "Power ON" button
on the front touch pad. Press the "Dispense"
button on the front touch pad, and dispense
approximately 12 ounces liquid.
Press the "Power OFF'
button on the front
touch pad.
To drain the remaining soap solution from the
dispenser, place a pail under the front drain tube
next to the front panel. Slowly remove the hook
drain plug from inside the mix tank. The soap
solution will now drain from the dispenser. Using
the spatula, direct the remaining soap solution to
the drain hole in the mix tank.
With the machine completely drained, you must
now disassemble, clean, sanitize and reassemble
your dispenser. Proceed and follow the
instructions as described in Part III of this
manual, Initial Cleaning Procedure.
IX – Technical Information
Model KW-77 – 120Vac/60Hz/Air
A) Refrigeration
Compressor MFG. – Danfoss
Horsepower – 0.17
FLA. – 1.1 amps
Locked Rotor Amps – 11.4 amps
Low Side Pressure – 14 psig
High Side Pressure – 140 psig
Condenser Cooling – Air
0
Refrigerant Type – R134a
OFF
Refrigerant Amount – 3.5 ounces
Metering type – Capillary tube
Condenser Fan Motor
Horsepower – 0.01
Full Load Amps – 0.88
RPM – 3000
B) Pump Drive Motor
Motor MFG. – General Electric
Motor Type – CSIR / ODP
Horsepower – 0.5
Full Load Amps – 8.8
Overload Type – Manual / Internal
Reset Location – Rear of motor casing