EXPAND SERIAL COMMAD FUNCTIONAL SPECIFICATION for LV-5210/7215/7210
8.4.7
CF_WBAL-COMMAND
COMMAND
"CF_WBAL-%1_%2" [CR]
"R" ------------- RED
%1
"G" ------------- GREEN
"B" ------------- BLUE
"000-063"-- Directly select color value by White Balance %1 determination
%2
"UP"------------ Color value for White Balance %1 determination +1
"DN"------------ Color value for White Balance %1 determination -1
Set the user Control value by white balance %1 determination.
The value set by this Command will not be saved to the projector.
Details
Therefore, when ALL OFF the projector, the value will return to the original
setting. (For STANDBYMODE, this value stays.) Only valid when it is in
the usual Power On state.
Acceptable
Response
Unacceptable
8.4.8
CF_COLTEMP COMMAND
COMMAND
"CF_COLTEMP_%1" [CR]
"000"........ XLow
"001"........ Low
%1
"002".......MID
"003"........ High
Set the Color Temp.(When it is in usual Power ON state, this is valid.)
The value set by this Command will not be saved to the projector.
Details
Therefore, when ALL OFF the projector, the value will return to the original
setting. (For STANDBYMODE, this value stays.) Only valid when it is in
the usual Power On state.
Acceptable
Response
Unacceptable
8.4.9
CF_PROGV COMMAND
COMMAND
"CF_PROGV_%1" [CR]
"L1"------ Select Progressive MODE L1
%1
"L2"------ Select Progressive MODE L2
Set/Cancel for Progressive. (When it is in usual Power ON state, this is
valid.)
The value set by this Command will not be saved to the projector.
Details
Therefore, when ALL OFF the projector, the value will return to the original
setting. (For STANDBYMODE, this value stays.) Only valid when it is in
the usual Power On state.
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"OFF"----cancel Progressive
"000" [CR]
"Error Code" [CR]
Page