DORMA-Glas UNIQUIN Montageanleitung - Seite 7

Blättern Sie online oder laden Sie pdf Montageanleitung für Inneneinrichtung DORMA-Glas UNIQUIN herunter. DORMA-Glas UNIQUIN 20 Seiten.

DORMA-Glas
Fig. 12
Inside T-joint, profile cut on site
A
Base profile 1
A1
Base profile 1.1
A2
Base profile 1.2
B
Base profile 2
C1
Cover profile 1.1 = Linear measure A1
C2
Cover profile 1.2 = Linear measure A2
D
Cover profile 2
E
Glass thickness
Procedure
1.
Place base profile 2 flush on base profile 1 at a right angle.
2.
Mark the legs of base profile 2 on base profile 1. Remove base
profile 2 and complete the markings up to the identification
groove.
3.
Separate the marked area from base profile 1.
4.
Insert base profile 2 into the cut-out and check.
5.
Cut all cover profiles
A2 = 6+E+24.5+3
Fig. 13
Profiles prepared
2023-08 / 16676
UNIQUIN Mounting profile
E+33,5
WN 059546 45532
5.3.2

Prepare outside T-joint

6
Fig. 14
Outside T-joint on the side of the base profile
Fig. 15
Example of a mounting with outside T-joint
A
Base profile 1
B
Base profile 2
C
Cover profile 1
D
Cover profile 2
E
Glass thickness
Installation preparation
46 (55)
7