Cansec Zodiac FR100 Installationshandbuch - Seite 15

Blättern Sie online oder laden Sie pdf Installationshandbuch für IP-Zugangssteuerungen Cansec Zodiac FR100 herunter. Cansec Zodiac FR100 15 Seiten.

Cansec Zodiac FR100 Installationshandbuch
DC ELECTRIC STRIKES – SAME POWER SOURCE
X
Do not use supplied
transformer in this configuration
Important: Same power source. Max. 12VDC. Reader requires 12VDC/500 mA
NOTES:
1. Use 1N400x series diode as shown, to prevent "back EMF" from
damaging the reader.
2. Ensure that the lock power is 12VDC with sufficient current to power
both the lock and the reader. The reader requires 12VDC/500 mA.
lock specifications from manufacturer.
Dry contact relay is rated at max. 1A
TM
Zodiac FR100
Installation Manual
Power source
for both
reader and
2
lock
See
Page 15 of 15
June 2014 • Rev. 1.2