Dormakaba TP/TA EASY Safe Montageanleitung - Seite 14
Blättern Sie online oder laden Sie pdf Montageanleitung für Inneneinrichtung Dormakaba TP/TA EASY Safe herunter. Dormakaba TP/TA EASY Safe 20 Seiten.
dormakaba mounting instructions
Note
65/55 mm DP = panel width - 4.5 mm
20 mm DP = panel width - 18 mm
DP
Fig. 32
65/55 mm DP
DP
Fig. 33
20 mm DP
2. Align the bottom rail according to the unit
drawing on the floor and on the ceiling.
3. Mark the drill holes and drill the holes.
4. Use suitable screws and dowels to secure the
bottom rail.
Fig. 34
Mounting the bottom rail
5. Laterally slide the side panel onto the bottom rail
at the top and bottom.
6. Align the side panel with a distance of 5 mm to
the wall.
14
TP/TA EASY Safe
Panel width
Panel width - 4.5
Panel width
Panel width - 18
WN 060028 45532
Note
The screws for securing the side panel are
not included.
The screw heads must end flush with the
door rail.
7.
Drill and screw the door rail and the bottom rail
at the bottom on the left and right.
50
Fig. 35
Screwing the door rail
4.9
Aligning the side panel
See Chapter 4.6
4.10 Mounting the cover profiles
Note
The recesses for the door strap or the lock
module, for example, are already provided in
the cover profiles.
1.
To ensure the cover profile fits firmly, bend the clip
cam at 3-4 points along the cover profile's length
if necessary.
Bending the clips cam
Fig. 36
2. Insert a slotted screwdriver between the rubber
seal and the cover profile and turn it.
‣
The clip cam is bent upwards.
3. Insert the rubber seal in the cover profile across
the entire length.
Mounting
50
2020-11