Dormakaba 8900 PT Installationsanleitung Handbuch - Seite 6
Blättern Sie online oder laden Sie pdf Installationsanleitung Handbuch für Intercom System Dormakaba 8900 PT herunter. Dormakaba 8900 PT 8 Seiten. Emf surface applied closer (no detector)
Auch für Dormakaba 8900 PT: Installationsanleitung Handbuch (10 seiten)
dormakaba 8900 PT/PTH Installation Instructions
3
Adjustments
Confirm closer spring size prior to making any
closing speed adjustments.
Do not back valve heads out beyond closer casting.
3.1 Adjust closing speeds: sweep, latch, backcheck, delayed action
Fig.5
L
-
+
S
-
+
3.2 Adjust hold open (optional)
Fig.6
3.2.1 Place the hold open mechanism in desired
position and tighten screw.
8900 Surface Applied Closers
6
+
-
Decrease
Sweep & Latch
Increase
Increase
Backcheck &
Delayed Action
Decrease
3.2.3 To enable: push white slide into hold open
3.2.4 To disable: pull white slide away from hold open
08279731
Door should close in 3 to 6 seconds from 90º.
Do not close valves completely.
-
+
3.2.2 To adjust hold open force:
•
To increase = turn CW
•
To decrease = turn CCW
mechanism.
mechanism.
Adjust closing speeds
Adjust hold open
-
+
09-2019