Canvas 085-1558-6 Montageanleitung Handbuch - Seite 10
Blättern Sie online oder laden Sie pdf Montageanleitung Handbuch für Außenkamin Canvas 085-1558-6 herunter. Canvas 085-1558-6 11 Seiten. York outdoor fire table

To obtain the best performance from your fire table, you must perform the following
storage and maintenance activities on a regular basis:
Allow at least 35 minutes for the fire table to cool down after
use, before disconnecting and removing the gas cylinder.
Store the gas cylinder in a dry, well-ventilated and
sheltered area protected from inclement weather and dust,
out of the reach of children, and not in a building, garage or
any other closed area.
The fire table may be stored indoors only if the cylinder is
disconnected and removed.
Keep the fire table area clear and free from combustible
materials, gasoline and other flammable vapours and liquids.
Installation and repair should be done by a qualified service person. The fire table
should be inspected before use and at least annually by a qualified service person.
More frequent cleaning may be required as necessary. It is imperative that the control
compartment, burner, and circulating air passageways of the fire table be kept clean.
If you disassemble the burner when cleaning the fire table, please reassemble it
according to the picture on the right to make sure the burner induction tunnel is on
and exactly covers the orifice base. It is imperative that the control compartment,
burner, and circulating air passageways of the fire table be kept clean. It is recommended
not to disassemble the burner.
Permanent installation and repair should be done by a qualified service person. The
fire table should be inspected annually by a qualified service person.
TROUBLESHOOTING
PROBLEM OBSERV
G as odour
Delayed ignition
Incorrect burner flame
ED
POSSIBLE CAUSE
G as leak
Low gas pressure
Clogged or dirty burner ports
Blocked orifice
Spent battery
Incorrect gas supply or
pressure Blocked orifice
Clogged or dirty burner ports
CORRECTIVE MEASURES
See " If you smell gas " on page 2.
C heck all gas connections.
C heck gas supply pressure.
C lean burner ports-see manual
section.
C heck orifice opening.
C hange new battery.
C heck gas supply pressure.
C heck and clean orifice opening.
C lean burner ports.
10